19
17.2 Altering the position of end switches:
Using the screw driver included in the delivery you can remove the end
switch cables from the guiding profile. After having released the locking
screw of the end switch, you can alter its position by moving or pulling the
cable of the end switch. When the end switch has reached the correct posi-
tion, you have to fix it again using the locking screw. The remaining cable of
the end switch is introduced into the crankcase.
1
7.3 Adjustment of end switch “OPEN “
Unlock the operator using the emergency release (see page 20, point 18
“emergency release “) and move the gate until it reaches the desired posi-
tion “OPEN “. Now exchange the connecting wires at the 3V button cell so
that the LED of the end switch “OPEN” will start to flash. Release the lock-
ing screw of the end switch “OPEN” and move it towards “ the end of the
driving rod
“ until the LED of the end switch “OPEN” ceases to flash. Now
the end switch “OPEN” has reached the correct position.