Installation SPIDER-SL
Release 06 01/2020
25
2.4.1
Connecting the 3-pin terminal block (device variants
with characteristic value HH)
Figure 2: 3-pin terminal block, characteristic value HH
Proceed as follows:
Verify the required conditions for connecting the voltage supply.
See “Requirements for connecting electrical wires” on page 7.
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires in the terminal block by tightening the terminal screws.
Mount the terminal block for the supply voltage and the ground by
plugging them in.
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range
12 V DC ... 24 V DC
Voltage range incl. maximum
tolerances
9.6 V DC ... 32 V DC
24 V DC
Plus terminal of the supply
voltage
0 V
Minus terminal of the supply
voltage
Functional ground connection
Table 2:
Type and specification of the supply voltage and pin assignment on the