26
Installation SPIDER-SL
Release 06 01/2020
2.4.2
Connecting the 3-pin voltage terminal with spring
(device variants with the characteristic value HK)
Figure 3: 3-pin voltage terminal with spring, characteristic value HK
Proceed as follows:
Verify the required conditions for connecting the voltage supply.
See “Requirements for connecting electrical wires” on page 7.
Remove the terminal connector from the device.
Open the terminal lock by pressing the corresponding lever with a
screwdriver.
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range
12 V DC ... 24 V DC
Voltage range incl. maximum
tolerances
9.6 V DC ... 32 V DC
24 V DC
Plus terminal of the supply
voltage
0 V
Minus terminal of the supply
voltage
Functional ground connection
Table 3:
Type and specification of the supply voltage and pin assignment on the
device
FR
24V
0V