background image

2

The performance features described here
are binding only if they have been expressly
guaranteed in the contract. We have
checked that the contents of the technical
publication agree with the hardware and
software described. However, it is not possi-
ble to rule out deviations completely, so we
are unable to guarantee complete agree-
ment. However, the details in the technical
publication are checked regularly. Any cor-
rections which prove necessary are contai-
ned in subsequent editions. We are grateful
for suggestions for improvement.

We reserve the right to make technical
modifications.

Permission is not given for the circulation
or reproduction of this document, its use or
the passing on of its contents unless gran-
ted expressly. Contravention renders the
perpetrator liable for compensation for
damages. All rights reserved, in particular
in the case of patent grant or registration of
a utility or design.

Copyright 
© Hirschmann 
Automation and Control GmbH 2018
All Rights Reserved

Note

We would point out that the content of
these operating instructions is not part of,
nor is it intended to amend an earlier or exi-
sting agreement, permit or legal relation-
ship. All obligations on Hirschmann arise
from the respective purchasing agreement
which also contains the full warranty condi-
tions which have sole applicability. These
contractual warranty conditions are neither
extended nor restricted by comments in
these operating instructions.

We would furthermore point out that for
reasons of simplicity, these operating
instructions cannot describe every
 conceivable problem associated with the
use of this equipment. Should you require
further information or should particular
 problems occur which are not treated in
sufficient detail in the operating instruc-
tions, you can request the necessary infor-
mation from your local Hirschmann sales
partner or directly from the Hirschmann
office (address: refer to chapter entitled
„Notes on CE identification“).

Safety Instructions

This manual contains instructions which
must be observed to ensure your own per-
sonal safety and to avoid 
damage to devices and machinery. The
instructions are highlighted with a warning
triangle and are shown as 
follows  according to the degree of endan-
germent:

z

Danger!

means that death, serious injury or
considerable damage to property

will

result if the appropriate safety

measures are not taken.

z

Warning!

means that death, serious injury or
considerable damage to property

can

result if the appropriate safety

measures are not taken.

z

Caution!

means that light injury or damage to
property can result if the appropria-
te safety measures are not taken.

Note:

is an important piece of information

about the product, how to use the product,
or the relevant  section of the documentati-
on to which particular attention is to be
drawn. 

Certified usage

Please observe the following:

z

Warning

The device may only be employed
for the purposes described in the
catalog and technical description,
and only in conjunction with external
devices and components recommen-
ded or approved by Hirschmann.
The product can only be operated
correctly and safely if it is transpor-
ted, stored, installed and assembled
properly and correctly. Furthermore,
it must be operated and serviced
carefully.

Safety Guidelines
Power Supply

Switch the basic devices on only when

the case is closed.

z

Warning!

The devices may only be connected
to the supply voltage shown on the
type plate.

The devices are designed for opera-
tion with a safety extra-low voltage.
Thus, they may only be connected
to the supply voltage connections
with SELV circuits with the
 restrictions for power sources  of
limited performance in accordance
with IEC/EN 60950-1.

First of all you connect the ground

connection, before you establish the further
connections. When you remove connec-
tions, you disconnect the ground connec-
tion last.

Relevant for North America:

The subject unit is to be suppplied by a
Class 2 power source complying with the
requirements of the National Electrical
Code, table 11(b).

Relevant for North America:

Power, input and output (I/O) wiring must
be in accordance with Class I, Division 2
wiring methods [Article 501-4(b) of the
National Electrical Code, NFPA 70] and in
accordance with the authority having juris-
diction.

Peripheral equipment must be suitable for
the location it is used in.

Use 60/75°C or 75°C copper(CU)wire only.

Safety Guidelines
Shielding Ground

Beware of possible short circuits when

connecting a cable section with conductive
shielding braiding.

Safety Guidelines Housing

z

Warning!

Only technicians authorized by
 Hirschmann are permitted to open
the housing.

Note:

The SPIDER is grounded via a pin of

the 3pin terminal block.

Make sure that the electrical installation

meets local or nationally applicable safety
regulations.

z

Warning!

The ventilation slits must not be
covered so as to ensure free air cir-
culation.

The distance to the ventilation slots
on the top and the bottom of the
housing has to be a minimum of 10
cm. 
The side distance of the SPIDER
4TX/1FX... and SPIDER 8TX... devi-
ces to neighbour devices has to be a
minimum of 2 cm if the ambient
temperature is higher than 50°C.

Never insert pointed objects (thin
screwdrivers, wires, etc.) into the
inside of the subrack! Failure to
observe this point may result in inju-
ries caused by electric shocks.

Note:

Only operate the device in switch

cabinets which comply with the fire enclo-
sure specifications described in EN 60950-1.

Note:

The housing has to be mounted in

upright position.

Safety Guidelines Environment

z

Warning!

The device may only be operated in
the listed ambient temperature
range at the listed relative air humi-
dity (non-condensing).

The installation location is to be selec-

ted so as to ensure compliance with the cli-
matic limits listed in the Technical Data.

To be used in an up to Pollution Degree

2 environment only (IEC 60664-1).

Staff qualification
 requirements

Note: 

Qualified personnel, as understood

in this manual and in the warning signs, are
persons who are familiar with the setup,
assembly, startup,  and operation of this
product and are appropriately qualified for

Summary of Contents for Hirschmann SPIDER Series

Page 1: ...network segments to the TP ports using twi sted pair cabling The SPIDER 1TX 1FX devices have one 10 100 MBit s twisted pair port RJ45 connectors and one 100 MBit s fiber optic port 100BASE FX Duplex SC connector It is possible to connect one data terminal equipments or other network segments to the TP ports using twisted pair cabling One further DTE or optical network component can be connected to...

Page 2: ...scription and only in conjunction with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Safety Guidelines Power Supply 䡺 Switch the basic devices on only when the case is closed z Warning The d...

Page 3: ...enginee ring standards trained or directed in the care and use of appropriate safety equipment in accor dance with the current standards of safety engineering trained in providing first aid General Safety Instructions 䡺 This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions z Warning Fail...

Page 4: ...T 10 100 DA STAT DA STAT Port 1 3 pin terminal block 3 pin terminal block 8 ports 10 100BASE T X RJ45 connectors autonegotiaton autopolarity autocrossing LED display elements Port 5 Port 4 Port 3 Port 2 4 ports 10 100BASE T X RJ45 connectors autonegotiaton autopolarity autocrossing P x P x DA STAT SPIDER 3TX SPIDER 1TX 1FX SPIDER 1TX 1FX SM Port 3 Port 2 Port 1 3 pin terminal block 3 ports 10 100B...

Page 5: ...rs the age of the learned addresses The SPIDER deletes address entries from the address table which exceed a certain age 300 seconds Note Restarting deletes the learned address entries Tagging IEEE 802 1Q The IEEE 802 1 Q standard designates the VLAN tag to be included in a MAC data frame for the VLAN and prioritizing func tions The VLAN tag consists of 4 bytes 2 bytes tag protocol identifier TPID...

Page 6: ...er snap on slide bar of the SPIDER to the standard bar and press it down until it locks in position 䡺 Fit the signal lines Notes The SPIDER is grounded via a pin of the terminal block Do not open the housing The shielding ground of the twisted pair lines which can be connected is electrical ly connected to the ground connection Fig 5 Assembling the SPIDER Fig 6 Dimensions 13 7 70 63 3 23 8 5 3 3 S...

Page 7: ...b SPIDER 4TX 1FX Ambient temperature 0 ºC to 60 ºC 32 ºF to 140 ºF SPIDER 3TX TAP SPIDER 5TX SPIDER 8TX Surrounding air SPIDER 1TX 1FX SPIDER 1TX 1FX SM SPIDER 4TX 1FX 40 ºC to 70 ºC 40 ºF to 158 ºF SPIDER 4TX 1FX EEC SPIDER 4TX 1FX ST EEC SPIDER 4TX 1FX SM EEC SPIDER 5TX EEC SPIDER 8TX EEC 40 ºC to 75 ºC 40 F to 167 F SPIDER 1TX 1FX EEC SPIDER 1TX 1FX SM EEC Storage temperature 40 ºC to 70 ºC 40 ...

Page 8: ...connection 100 MBit s singlemode SM SPIDER 3TX TAP 3 TP TX ports RJ45 sockets 10 100 MBit s SPIDER 5TX SPIDER 5TX EEC 5 TP TX ports RJ45 sockets 10 100 MBit s SPIDER 8TX SPIDER 8TX EEC 8 TP TX ports RJ45 sockets 10 100 MBit s Displays Equipment status 1 x green LED P power supply voltage present Port status SPIDER 1TX 1FX 2 x green LEDs DA STAT data link status 1 x yellow LEDs 10 100 data rate TP ...

Reviews: