background image

9

Scope of delivery

Rail Switch RS2-xTX/xFX EEC incl.

terminal block for supply voltage
description and operating instructions

Order number

Rail Switch RS2-3TX/2FX EEC

943 771-001

Rail Switch RS2-3TX/2FX-SM EEC

943 772-001

Rail Switch RS2-4TX EEC

943 819-001

Rail Switch RS2-4TX/1FX EEC

943 773-001

Rail Switch RS2-4TX/1FX-ST EEC

943 119-002

Rail Switch RS2-4TX/1FX-SM EEC

943 774-001

Accessories

Ethernet manual

943 320-011

Manual
Basics Industrial Ethernet and TCP/IP

280 720-834

Rail Power Supply RPS 30

943 662-003

Rail Power Supply RPS 80 EEC

943 662-080

Rail Power Supply RPS 120 EEC

943 662-120

Summary of Contents for HIRSCHMANN RS2-3TX/2FX EEC

Page 1: ...e four 10 100 MBit s twisted pair ports 10 100BASE TX RJ45 connectors and one 100 MBit s fiber optic port 100BASE FX Duplex SC connector or ST connector on R2 4TX 1FX ST EEC The RS2 4TX EEC module has...

Page 2: ...components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must...

Page 3: ...Li LCable and b max Cable Length Ca Ci CCable The lower value of a and b is to apply CableL inductance per unit length of used cable CableC capacitance per unit length of used cable Other C parameters...

Page 4: ...an 119 V Connectors shall be connected or dis connected exclusively in dead voltage state DIP switches shall be switched exclusi vely in dead voltage state Safety Guidelines Environment z Warning The...

Page 5: ...a cross over or straight cable 1 3 SPECIFIC FUNCTIONS OF THE F O INTERFACE Link control The RS2 xTX xFX EEC monitors the connec ted F O line for interrupts using idle signals during frame pauses in a...

Page 6: ...wer P1 and P2 LEDs for data link status DA STAT 1 to 5 FAULT LED LEDs for power P1 and P2 LEDs for data link status DA STAT 1 to 5 on the RS2 4TX EEC FAULT LED 2 3 4 DA STAT 1 2 P 1 DA STAT FAULT 2 3...

Page 7: ...3 Port 2 Port 4 Suppress message about link status via indicator contact RS2 4TX EEC LA1 0 1 LA5 LA3 LA2 LA4 Port 1 Port 5 Port 3 Port 2 Port 4 Suppress message about link status via indicator contact...

Page 8: ...al EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 Radiated emission EMC EN 55022 Class A CFR 47 Part 15 Class A Stabilit...

Page 9: ...FX SM EEC 943 772 001 Rail Switch RS2 4TX EEC 943 819 001 Rail Switch RS2 4TX 1FX EEC 943 773 001 Rail Switch RS2 4TX 1FX ST EEC 943 119 002 Rail Switch RS2 4TX 1FX SM EEC 943 774 001 Accessories Ethe...

Page 10: ...Automation and Control GmbH Stuttgarter Stra e 45 51 72654 Neckartenzlingen Germany Tel 49 0 1805 14 1538 Fax 49 0 7127 14 1551 E mail hac support belden com Internet http www hirschmann com 039 651 0...