Installation RS20/22/30/32/40
Release 03 06/2013
19
Examples for product name
l.
Devices with ports with product code E2 or EE: only certification “A” available (see product
code for item 16).
m. For RS20-0900..., RS20-1700..., RS20-2500...;
RS22-0900..., RS22-1700..., RS22-2500...
n. For RS20-0900..., RS20-1700..., RS20-2500...;
RS22-0900..., RS22-1700..., RS22-2500...
o. Not in combination with “04×100 Mbit/s Ethernet”.
p. In combination with “2nd uplink port” “ZZ” and “1st uplink port” “OO”.
q. In combination with “2nd uplink port” “ZZ” and “1st uplink port” “OO”.
r.
Not in combination with “04×100 Mbit/s Ethernet”.
s. With a UL-508, ATEX or ISA 12.12.01 certification, the maximum operating temperature for
the standard ‘S’ temperature range for PoE-capable devices (RS22-..., RS32-...) +50 °C.
t.
The extended ‘E’ temperature range for the PoE-capable devices is
−
40 °C to +60 °C.
With a UL-508, ATEX or ISA 12.12.01 certification, the maximum operating temperature for
the extended ‘E’ temperature range for PoE-capable devices (RS22-..., RS32-...) +50 °C.
u. Not when using GG or G2 transceivers.
v. The extended ‘T’ temperature range for PoE-capable devices is
−
40 °C to +60 °C.
With a UL-508, ATEX or ISA 12.12.01 certification, the maximum operating temperature for
the extended ‘T’ temperature range for PoE-capable devices (RS22-..., RS32-...) +50 °C.
w. Not when using GG or G2 transceivers.
x. In combination with “2nd uplink port” “ZZ” and “1st uplink port” “OO”.
y. Not for PoE-capable devices (RS22-..., RS32-...).
z. For PoE-capable devices (RS22-..., RS32-...).
aa. Without railway certification EN 50155 (Train).
RS2
0
-
RS20-
Rail Switch without gigabit ports
09
09
9 × 100 Mbit/s Ethernet ports
00
00
0 × 1000 Mbit/s Ethernet ports
MM
MM
Port 1 + 2 = 2 × Multimode FX, DSC, 100 Mbit/s
M2
M2
Port 3 = Multimode FX, DSC, 100 Mbit/s
S
S
Temperature range standard: 0 °C ... +60 °C
D
D
Voltage range: 9.6 V DC to 60 V DC or 18 V AC to 30 V AC
A
A
Certifications: CE, UL 508, ISA 12.12.01 (UL 1604)
P
P
Software variant: Professional
Table 3:
Example of RS20 with 3 uplink ports: RS20-0900MMM2SDAP
RS30-
RS30-
Rail Switch with gigabit ports
08
08
8 × 100 Mbit/s Ethernet ports
02
02
2 × 1000 Mbit/s Ethernet ports
O6
O6
Port 1 = SFP slot, 1000 Mbit/s
T1
T1
Port 2 = twisted pair TX, RJ45 connector, 1000 Mbit/s
T
T
Temperature range extended: -40 °C to +70 °C
D
D
Voltage range: 9.6 V DC to 60 V DC or 18 V AC to 30 V AC
A
A
Certifications: CE, UL 508, ISA 12.12.01 (UL 1604)
E
E
Software variant: Enhanced
Table 4:
Example of RS30 with 2 uplink ports: RS30-0802O6T1TDAE