Installation RED25
Release 01 02/2015
33
Climatic condi-
tions during
storage
Ambient air temperature
d
−
40 ºF ... +185 ºF (
−
40 ºC ... +85 ºC)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Signal contact
FAULT
See “Requirements for connecting electrical conductors” on page 6.
Switching current
max. 1 A
Switching voltage
max. 60 V DC
Relevant for North America:
max. 30 V DC, resistive load
Pollution degree
2
Protection
classes
Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP20
a. Reduction of the maximum permitted ambient air temperature under specific conditions
b. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
c. Use SFP transceivers with the “EEC” extension only, otherwise the temperature range
+32 °F ... +140 °F (0 °C ... +60 °C) applies.
d. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
Summary of Contents for Hirschmann RED25 Series