Page
41
of
100
OpEdge
Industrial Edge Gateway – Release 01.0.00 – 10/2022
5.3.2 LAN Configuration
The
LAN Configuration
defines the type of Ethernet connection for a port, i.e. static or dynamic.
To create a LAN configuration:
1
Click the
Networking
tab on the OpEdge configuration webpage.
2
Under
LAN Configuration
, click the
A
DD
LAN
button.
Note:
The user can add a maximum of seven LAN ports.
3
Select the
Mode
:
D
YNAMIC
or
S
TATIC
.
For
S
TATIC
configuration, enter the following parameters:
Parameter
Description
IP Address
Static IP Address for the port.
Subnet Mask
Subnet mask of the IP Address.
Gateway
Default IP Address of the OpEdge.
VLAN ID
VLAN identification number.
4
Click
A
PPLY
to save the changes.
5
To assign a LAN Configuration to a specific OpEdge Ethernet port, click the
Interfaces