- 31 -
Error
code
Error Cause
Solutions
E47
Error in the monitored
write/ read memory.
The CRC verification
of the monitored
write/read memory
provides an
incoherent result
The
CRC
sign
of
the monitored
write/read memory
is wrong
Buffering
battery is tested no
current (1kOhm
,
<
2V).
Controller
defect
Re-start
LMI
Change
the
buffering battery of
controller
Change
controller
E51
Crane data file fault
No
readable
crane data file
Flash-EPROM
defect
Up
date
crane
data file
Change
Flash-EPROM
E52
Loading curvilinear
figure
No
readable
crane performance
table
Flash-EPROM
defect
Update
effective
crane data file
Change
controller
E53
Wrong setting of
min. analogue
length1, angle1 and
pressure1
Not
support
analogue output
Set correct Flag
at DGA 6.i.2
E56
Crane data file fault
No
effective
data file during
adjustment
Flash-EPROM
defect
Resume
and
update effective
crane data file
Change
controller
E57
Crane serial data file
fault
No
effective
data file in the
adjusting data file
Flash-EPROM
defect
Update
effective
data file by changing
and saving
datas((OM, limits)
Change
controller