- 21 -
Press F4 key at the main display to enter into Reeving setup display.
F3
:
Confirm Reeving (After
confirmation, Current REEV will
change to New Reev setting)
F4
:
Reset the Reeving to zero.
F5
:
Back to the main display
Reeving setup interface
Set Reev interface
To change reave setting (parts of line of chosen hookblock), push N (F4 button)
to reset. Then enter the proper parts of the line of the chosen hookblock (using
numeric keys). Press Y (F3 button) to confirm change. NOTE: Current REEV
will change to New Reev setting. Push
◄┘
(F5 button) to return to screen.
5.4 Error Code Reference Table
When the system is malfunction, the error code will appear at the main
display.Through the error code information in the table, crane operators and
service engineers can better understand what the error code stands for, and
quickly find out the fault reasons and suggested solutions.
Press F4 key at the main display to enter into error code informatoin display
:
F3
:
Scroll up for the previous error
code information
F4
:
Scroll down for the next error code
information
F5
:
Back to the main interface
Error code query interface
Summary of Contents for Hirschmann HC4900
Page 38: ...34 9 HC4900 Connecting Diagram...