Installation EAGLE40
Release 02 08/2020
43
EMC and immunity
Note:
You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See table 5 on page 16.
EMC interference emission
Standard
applications
Radiated emission
EN 55032
Class A
FCC 47 CFR Part 15
Class A
EN 61000-6-4
Fulfilled
EMC interference immunity
Standard
applications
Electrostatic discharge
EN 61000-4-2
Contact discharge
± 4 kV
EN 61000-4-2
Air discharge
± 8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 1000 MHz
10 V/m
1.4 GHz ... 6.0 GHz
3 V/m
Fast transients (burst)
- power supply connection
EN 61000-4-4
±2 kV
Fast transients (burst)
- data line
EN 61000-4-4
± 1 kV
Voltage surges - power supply connection
EN 61000-4-5
line/ground
± 1 kV
EN 61000-4-5
line/line
± 0.5 kV
Voltage surges - data line
EN 61000-4-5
line/ground
± 1 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V