Installation EAGLE40
Release 02 08/2020
25
Figure 1: Pin assignment of the V.24 interface and the DB9 connector
1.8.2
DB9 port
Note:
EAGLE40-07 devices have a DB9 port for console access. The port is
labeled "CONSOLE". The "COM" port has no functionality in the current
release. For information about the position on the device:
See “Front view”
A serial interface is provided on the DB9 port for the local connection of an
external management station (VT100 terminal or PC with corresponding
terminal emulation). This enables you to set up a connection to the
Command Line Interface CLI and to the System Monitor.
The socket housing is electrically connected to the front panel of the device.
The DB9 port is electrically insulated from the supply voltage.
1.8.3
USB interface
Note:
For information about the position on the device:
See “Front view” on
or
The USB socket has an interface for the local connection of an
AutoConfiguration Adapter ACA21. It is used for saving/loading the
configuration data and diagnostic information, and for loading the software.
The USB interface has the following properties:
Supports the USB master mode
Supports USB 3.0 (data rate max. 480 MBit/s)
Connector type A
Supplies current of max. 500 mA
VT 100 terminal settings
Speed
115200 Baud
Data
8 bit
Stop bit
1 bit
Flow control
none
Parity
none
RJ45
DB9
GND
DT
TX
RX
DCD
DSR
RTS
CTS
4
5
2
3
6
7
1
8
5
4
3
2
1
6
7
8
RJ45
DB9
1
8
Summary of Contents for HIRSCHMANN EAGLE40
Page 52: ......