Network range
Note:
The line lengths specified for the transceivers apply for the
respective fiber data (fiber attenuation and BLP/dispersion).
MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
Power consumption/power output
Product
code
M-SFP-...
Wave
length
Fiber
System
attenuatio
n
Example
for F/O line
length
a
a. including 3 dB system reserve when compliance with the fiber data is observed
Fiber
attenuatio
n
BLP
b
/
dispersion
b. Using the bandwidth length product is inappropriate for expansion calculations.
-SX/LC... MM 850 nm
50/125 µm
0-7.5 dB
0-550 m
3.0 dB/km
400 MHz×km
-SX/LC... MM 850 nm
62.5/125 µm 0-7.5 dB
0-275 m
3.2 dB/km
200 MHz×km
-LX/LC... MM 1310 nm
c
c. With F/O adapter compliant with IEEE 802.3-2002 clause 38 (single-mode fiber offset-launch
mode conditioning patch cord)
50/125 µm
0-10.5 dB 0-550 m
1.0 dB/km
800 MHz×km
-LX/LC... MM 1310 nm
c
62.5/125 µm 0-10.5 dB 0-550 m
1.0 dB/km
500 MHz×km
-LX/LC... SM 1310 nm 9/125 µm
0-10.5 dB 0-20 km
d
d. including 2.5 dB system reserve when compliance with the fiber data is observed
0.4 dB/km
3.5 ps/(nm×km)
-LH/LC... LH 1550 nm
9/125 µm
5-22 dB
23-80 km 0.25 dB/km 19 ps/(nm×km)
-LH+/LC
LH 1550 nm
9/125 µm
15-30 dB
71-108 km 0.25 dB/km 19 ps/(nm×km)
-LH+/LC
LH 1550 nm
9/125 µm
15-30 dB
71-128 km 0.21 dB/km
(typically)
19 ps/(nm×km)
Table 21: Fiber port 1000BASE-FX (SFP fiber optic Gigabit Ethernet Transceiver)
10/100/1000 Mbit/s twisted pair port
Length of a twisted pair segment
max. 100 m (for cat5e cable)
Conditions
Maximum
power consumption
Power output
When equipped with 1 WLAN module 12.95 W
44.19 BTU (IT)/h
When equipped with 2 WLAN
modules
17.5 W
59.71 BTU (IT)/h