Installation BAT-F
Release 09 08/2015
41
2.5.2
Supply voltage with the characteristic value K
Connect the wires for the supply voltage and the protective grounding
according to the pin assignment with a suitable socket.
WARNING
ELECTRIC SHOCK
Install this device solely in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.
Type of the
voltages that
can be
connected
Specification of the supply
voltage
Pin assignment on the device
DC voltage
Rated voltage range DC
60 V ... 250 V
PE Protective conductor
Voltage range DC incl.
maximum tolerances
48 V ... 320 V
P+ Plus terminal of the
supply voltage
P- Minus terminal of the
supply voltage
AC voltage
Rated voltage range AC
110 V ... 230 V, 50 Hz ...
60 Hz
PE Protective conductor
Voltage range AC incl.
maximum tolerances
88 V ... 265 V, 47 Hz ... 63 Hz
L
Outer conductor
N Neutral conductor
Table 8:
Supply voltage with the characteristic value K: type and specification of
the supply voltage, connections
P-
P+
PE
N
L
PE