42
Specifications
Kula AV Mainframe
Mav Remote Specifications
Mainframe PSU Information (covering all Kula AV mainframes)
Mainframe Reference/GPIO
Reference/
Sync Input
/Output
1x Tri-Level depending on output standard
1x On-line Switchable between analogue 3Gbps, HD Tri-level Sync and
analogue SD sync
GPIO
3 x 25 Way D-type programmable GPIO Tally with TTL-level/contact-closure
inputs for GPI
Mav Remote
Connector
Description
Video Output
1x Monitor Output
USB
2x USB 2 Connectors
Network
1x 10/100/1000 base T, Auto - MDX/MDXI on RJ45 connectors
Connections to
MAV modules
8x RJ45 connectors for Comms and 2x +12V 0.42A power supply
Connection to other MAV modules
NOT Ethernet, connections must be direct to MAV modules.
Do Not
use
network switches or hubs.
CAT5 or above cables - crossover cables are
Not
suitable.
Mav Remote Power Supplies
Power Supply
Description
To the
Mav Remote
2x Fully independent external PSU modules with separate mains power feeds
via 2x 10A IEC leads.
Output from each PSU = 12V DC 100W via Kycon KPPX 4 Pin or Compatible
connectors to the Mav Remote.
2 supplied as standard per Mav Remote, One PSU provides Dual Redundancy.
Mav Remote External Mains Power Supply Requirements
Voltage
100V - 240V 50/60Hz
Power
Less than 100Watts (per Mav Remote)
Mainframe Power Supplies
Mainframe
Two fully independent hot-swappable PSU modules, with separate mains
power feeds via 2 x IEC sockets. Dual Redundant requires two fully
independent PSU modules; with separate mains power feeds via 2 x IEC
socket.
Mainframe Power Supply Requirements
Voltage
100V - 240V 50/60Hz, 5-2A
Power
400 Watts Max.