DURAFLO™ 18 GPM PUMPING STATIONS
1MANUL375
Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470* Ph (248) 349-7010 * Fax (248) 380-9681
13
Assembly
2) Install the outlet plumbing from the outlet port of the Distribution Manifold to the desired piece of
equipment. See the image below.
Note:
The outlet feed should be flexible hose from the unloader valve to any hard piping, solenoid
or tees.
Hose MUST be rated for a minimum pressure of 1500 PSI. Remember that the plumbing has
direct bearing on pressure at the nozzle (massive pressure drops are common to an incorrectly
installed system).
3) Install 3 phase wiring in accordance with any and all local and national codes (direction is
reversible).
Use caution, this machine starts automatically. Avoid contact with high pressure spray, as
serious personal injury may occur.
Outlet Port
Disribution Manifold