INSTALLATION INSTRUCTION
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1
408
785 5200
© 2020 Bel Power Solutions & Protection
BCM.00428_AC
AC INPUT
100
–
277 V ~, 17
–
12.5 A, 50/60 Hz
240
–
380 V , 13
–
9 A
(Input selection is automatic; no manual change is required.)
OUTPUTS
V1 (12.3 V): see below table
Vsb (12.0 V):
MODEL
INPUT VOLTAGE
AMBIENT TEMPERATURE: 50°C
AMBIENT TEMPERATURE: 60°C
TET3000-12-069RA
100-200 VAC
81.3-244 A
65 -195.2 A
200-277 VAC, 240-380 VDC
244 A
195.2 A
AMBIENT TEMPERATURE: 45°C
TET3200-12-069RA
100-200 VAC
92-260 A
75-211 A
200-277 VAC, 240-380 VDC
260 A
211 A
CAUTION
These component level power supplies are intended exclusively for installation within other equipment by an industrial assembly operation or by professional installers.
This is a Class 1 power supply; the unit must be properly connected to earth ground in end use. A component power supply should be installed in end-use equipment
according to the requirements of the safety standard used for that equipment. This power supply is not designed to be operated outside of an enclosure which provides
a means of mechanical, electrical, and fire protection. To maintain ES1 requirements, the outputs should not be connected together in any manner which causes the total
output voltage to exceed 60 VDC.
PROTECTIVE EARTHING
The Power Supply must be properly grounded to mains protective earthing termination at end use.
WARNING
This is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.
声明
-
此为
A
级产品,在生活环境中,
该产品可能会造成无线电干扰。
在这种情况下,可能需要用户对其干扰采取切实可行的措施。
ENVIRONMENTAL CONDITIONS
TRANSPORTATION & STORAGE:
Ambient Temperature Range: -40 °C to +70 °C
Relative Humidity Range: 5% to 95% RH Non-Condensing
Altitude: 0 to 13000 meters ASL
OPERATION
Ambient Temperature Range: -40°C to +60°C (See output table for details)
Relative Humidity Range: 7% to 93% RH Non-Condensing
Altitude: 0 to 2000 meters ASL at 0 °C to +50°C (TET3000-12-069RA)
0 to 2000 meters ASL at 0 °C to +45°C (TET3200-12-069RA)
0 to 5000 meters ASL at 0 °C to +40 °C
SAFETY APPROVALS
Approved to the latest version of the following safety standards: UL/CSA 62368-1, IEC/EN 62368-1 and IEC/EN 60950-1.
FUSING
CAUTION: DOUBLE POLE/NEUTRAL FUSING.
Fuses F300 and F301 are rated 25 A, 500 V/500 V (fast acting).
Equipment is rated higher than 16 A. Type of connection to Mains must be determine in the end use equipment.
SERVICING
In case of failure, the Power Supply must be returned to a Bel Power Solutions Authorized Service Center. There are no user serviceable parts in the Power Supply.
LIMITED WARRANTY
Bel Power Solutions warrants each power supply of its manufacture for a period of two years from the date of original shipment. This warranty applies to defects in
materials and workmanship that result in non-performance to published specifications. The product(s) must be returned to a Bel Power Solutions Authorized Service
Center for repair with a Bel Power Solutions preassigned RMA number.
Bel Power Solutions assumes no liabilities for consequential damages of any kind through the use or misuse of its products by any user. No other obligations are
expressed or implied.
Please note that the specifications, terms, and conditions stated are subject to change without notice.
NUCLEAR AND MEDICAL APPLICATIONS
Bel Power Solutions products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous
environments, or nuclear control systems without the express written consent of the respective divisional president of Bel Power Solutions.
TECHNICAL REVISIONS
The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to
change without notice.