BEL DIGITAL AUDIO
BMA2-4SHD
BM-A series serial protocol
2006 BEL (Digital Audio) Ltd
24
Version 0.8
Commands
Commands from the remote controller to BM-A series unit(s).
Code(Hex) Function
Reply
80
General prompt for a reply
C0 - ACK (OK)
C1 - NAK (send again)
81
Use first data char as a second command
ACK
82
Request unit identifier
C2.
83
Set up switches Data count =5 See below for format
ACK
84
Set up alarm functions Data count=2 See below for format
ACK
85
Request Detail
C5
86
Request Switches
C6
Replies
Replies, when requested (e.g. 82), will consist of frames that contain the original command
value plus 0X40. So a request for an ident, 0x82, will elicit a reply of a frame containing 0xC2
and the ident string. (BM-A series model Vn.n)