Bargraph scales
The following bargraph ballistics may be selected using internal switches.
Scale type
Range
Attack
Fallback
AES/EBU:
60dB (0 to -60dB)
1ms
1.5Sec per 20dB decay
DIN PPM:
55dB (+5 to -50dB)
10mSec
1.5Sec per 20dB decay
VU:
23dB (+3 to -20dB)
300mSec
300mSec
BBC PPM:
+12 to-12dB - mark 7 to 1
10mSec
2.85Sec - mark 7 to 1
VU EXT:
80dB (+20 to -60dB)
300mSec
300mSec
NORDIC:
54dB (+12 to -42dB)
5mSec
1.7Sec per 20dB decay
BMA2-4SHD scale ballistics
Stick-on scale graticules, which may be applied to the space between the front-panel
bargraphs, are supplied with the machine.
BMA2-4SHD scale graticules
Note:
Bargraph color transition points and peak hold decay may also be adjusted
internally.
Refer to the Configuration chapter for switch settings and graticule fitting