12 / EN
Washer-Dryer / User’s Manual
90 cm
90
40
90
40
90 cm
90 cm
min.40
90 cm
90
40
90
40
90 cm
90 cm
min.40
90 cm
90
40
90
40
90 cm
90 cm
min.40
• Connect the hose to a minimum height of
40 cm and a maximum height of 90 cm.
• If the hose is run along the floor (or at less
than 40 cm above it) and raised later on,
water drain becomes difficult and laundry
may come out extremely wet. Therefore,
observe the heights described in the figure.
• To prevent flowing of dirty water back into
the machine and to allow for easy discharge,
do not immerse the hose end into the dirty
water or do not drive it in the drain more
than 15 cm. If it is too long, cut it short.
• The end of the hose should not be
bent, it should not be stepped on
and the hose must not be pinched
between the drain and the machine.
• If the length of the hose is too short, add an
original extension hose. Length of the hose
may not be longer than 3.2 m. To avoid water
leak failures, the connection between the
extension hose and the drain hose of the
product must be fitted well with an appropriate
clamp as not to come off and leak.
3.6 Adjusting the feet
A
CAUTION!
• Adjust feet so that the product will be
balanced in the location it will be used.
• Balance the machine by adjusting the feet.
• Check for any play by pressing the
product from upper diagonal edges.
• Otherwise, the product may move
from its place and cause crushing,
noise and vibration problems.
• Do not use any tools to loosen
the lock nuts. Otherwise, the
lock nuts may get damaged.
a) Loosen the lock nuts on the feet by hand.
b) Adjust the feet until the product stands level
and balanced.
c) Tighten all lock nuts again by hand.
3.7 Electrical connection
Connect the product to a grounded outlet
protected by a 16 A fuse. Our company shall
not be liable for any damages that will arise
when the product is used without grounding
in accordance with the local regulations.
• Connection must comply with
national regulations.
• The wiring for the electrical outlet circuit
must be sufficient to meet the appliance
requirements. Use of a Ground Fault Circuit
Interrupter (GFCI) is recommended.
• Power cable plug must be within
easy reach after installation.
• If the current value of the fuse or breaker
in the house is less than 16 Amps, have a
qualified electrician install a 16 Amp fuse.