background image

Split floor-standing air conditioner

 / User Manual

3 / 21 EN

1  Instructions to users 

4

1.1  Instructions for removal and repairs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

2  The name of each part and its function 

7

2.1  Indoor unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

2.2  Outdoor unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

2.3  Operation panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

2.4  Display screen 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2.5  Display screen 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

3  Use of operation panel 

13

3.1  Operation of mode change between Cool/Dry/Heat/Fan  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

4  Use of remote controller 

14

4.1  Operating machine in selected modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.2  Timer operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.3  Sleep operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

4.4  Replacement of batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

5 Maintenance 

18

5.1  Phenomena diagnosis and treatment  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Contents

Summary of Contents for BFYH 500

Page 1: ...BFYH 500 BFYH 501 Split floor standing air conditioner User Manual EN RU ...

Page 2: ......

Page 3: ...e user manual and all other accompanying documents carefully before using the product and keep it as a reference for future use If you handover the product to someone else give the user manual as well Follow all warnings and information in the user manual Meanings of the symbols Following symbols are used in the various section of this manual C Important information or useful hints about usage A W...

Page 4: ...2 Outdoor unit 8 2 3 Operation panel 9 2 4 Display screen 1 10 2 5 Display screen 2 11 3 Use of operation panel 13 3 1 Operation of mode change between Cool Dry Heat Fan 13 4 Use of remote controller 14 4 1 Operating machine in selected modes 15 4 2 Timer operation 15 4 3 Sleep operation 16 4 4 Replacement of batteries 17 5 Maintenance 18 5 1 Phenomena diagnosis and treatment 20 Contents ...

Page 5: ...ther inflammables near the inlet or outlet do not spray such articles directly against the units A Operate the machine only under the nominated voltage and frequency and with corresponding protective devices Never use copper wires to substitute the fuses which might lead to operational faults or fire hazards A The grounding terminal of the units must be well connected to the grounding of the power...

Page 6: ...me the power source should be disconnected for the sake of safety and energy saving A In the case that the breaker is frequently disconnected you should stop the operation of the machine and contact the dealer or our Co authorized maintenance shop When you restart the operation after a long period of non operation you should carefully check the air conditioner and the wire connection If the electr...

Page 7: ...to be removed for installation elsewhere or for repairs please contact our company dealer or authorized technicians In case of occurrence of abnormality burning smell for example please stop the operation of the unit disconnect the power and contact our company dealer or authorized technicians 1 Instructions to users ...

Page 8: ...6 1 Up down air direction guides For adjusting the vertical air delivery directions 2 Left right air swinging fins For adjusting horizontal air delivery directions 3 Display screen 4 Air inlet grille 5 Bottom panel 6 Operation panel 7 Air Outlet 2 The name of each part and its function ...

Page 9: ...of the air conditioner when it is running in refrigeration or dehumidification status the air conditioner will not stop supplying air immediately as the air conditioner is performing mould proofing functions The upper slide plate will delay for 30 seconds and then automatically close Features and appearance will vary AII the figures give a demonstration to introduce the function ...

Page 10: ...temperature is 32 C 5 Temp key Press the key once to reduce the set temperature by 1 C the lowest temperature is 16 C 6 Fan speed selection key Press the key to set your favorite air flow rate Low Middle High 7 Swing button Press this button changes the Up Down flap mode natural flow swing or fixed wind 8 Air flow button This button used for selection of the left right air flow direction whenever ...

Page 11: ...perature equals to or is lower than 10 C the function of dehumidifying cannot be used When room temperature equals to or is lower than set temperature the AC unit stops for a period of time to save energy The AC unit is equipped with automatic defrosting function and the heat operation indicator on the display screen flashes when the machine defrosts The AC unit with heat pump has auxiliary electr...

Page 12: ...indicator 3 The electric auxiliary heat 4 Key lock indicator 5 Room set temperature and malfunction code indicator 6 High speed indicator 7 Swinging wind indicator 8 Middle speed indicator 9 Low speed indicator 10 Fan operation indicator 11 Timer indicator 12 Auto operation indicator 13 Cool operation indicator 2 The name of each part and its function ...

Page 13: ... energy The AC unit is equipped with automatic defrosting function and the heat operation indicator on the display screen flashes when the machine defrosts The AC unit with heat pump has auxiliary electric heating function which will automatically turns on or off according to room temperature during heating operation to achieve the best heating result If you turn on the machine immediately after i...

Page 14: ... set desirable air flow rate The fan operates in low speed under the mode of Dry 5 Press On Off key once again to stop If you turn on the machine immediately after it is turned off the machine with time lapse starting function will automatically turn on the machine after 3 minutes to protect it C Note Adjust the up down or left right air flow direction by pressing the Swing or Air flow button of r...

Page 15: ...eat Fan Hold On Off 4 Use of remote controller 1 Fan speed indicator Indicates the set air rate 2 Sleep indicator Indicates during sleep operation 3 Turbo indicator Indicates during Turbo operation 4 Air flow indicator Indicates selected flap mode 5 Key lock indicator 6 Set temperature button This button sets the room temperature 7 Swing button This button changes Up Down air flow direction natura...

Page 16: ...d display indicates Press the Air flow button to choose the left right air flow direction you want swing or fixed wind It would be automatically set at fixed wind air flow direction in Dry mode A Warning Please do not adjust the guide blades of air outlet by hand directly or which can damage the parts of the machine 4 2 Timer operation Set turning off time Set the time for the unit to turn off and...

Page 17: ...e machine The timer can make the setting in the range from 1 24 hours Every the button is pressed indication change is the following sequence 1 2 24 cancel no indication 1 3 Afterthesettingofthetimedswitch on thedigitsshownonthedisplayscreenwillgodownby1for everyelapsedhour Thedisplayeddigitsindicatetheremainingtimepriortothetimedswitch on Releasing procedure When the indication on display screen ...

Page 18: ...to be used for replacement If the remote controller is not to be used for long time take out the batteries so as to prevent the leakage of the electrolyte from damaging the controller If when the remote controller is at abnormal state you can take out the batteries on the back cover to clear off the display Slidethebackcover CLK button RST button It does not work on this model Unload the back Cove...

Page 19: ...3 Cleaning of the filter screen Gently pat the screen or use a vacuum cleaner to do the cleaning lf too much filth is accumulated on the screen a small amount of neutral detergent solution can be used for the cleaning After the cleaning the screen must be dried in air and be put back into place C Note Do not place the air filter screen under the exposure of sunlight or near an over to dry do not u...

Page 20: ...e and grounding wire are in proper state 4 Check and confirm that there is any bending or raised ends or blockage of the drainage tubes 5 Make sure that the air filter screen is properly in place before operating the machine If the machine is operated with air filter screen removed dust and foreign objects will result in faulty performances of the air conditioner 6 After the operational seasons 1 ...

Page 21: ...ed due to changes of temperature which results in the friction of these parts This is not a performance fault The cooling is great When cooling is in operation sometimes the haze emits from the air outlet which cause is that when the indoor temperature and humidity is higher the indoor air is rapidly refrigerated after the indoor temperature and humidity lowers the haze will disappear Please read ...

Page 22: ...Check whether the voltage of the battery in the remote controller is enough or please replace the battery 4 When the remote controller displays obscurely please replace the battery When the following cases happen please stop operation disconnect the power source then contact our co dealer of the authorized maintenance shop The fuse is burned out frequently the current leakage switch switches off f...

Page 23: ... рекомендуем вам внимательно ознакомиться с настоящим руководством и всеми сопутствующими документами а также сохранить их для использования в будущем При передаче устройства другому лицу не забудьте передать и руководство Следуйте всем предупредительным знакам и указаниям в руководстве Значение символов Данные символы используются в различных разделах руководства C Важная информация или полезные ...

Page 24: ...ь управления 29 2 4 Экран дисплея 1 30 2 5 Экран дисплея 2 31 3 Использование панели управления 33 3 1 Переключение режимов работы Cool Охлаждение Dry Осушение Heat Обогрев Fan Вентилятор 33 4 Использование пульта дистанционного управления 34 4 1 Эксплуатация кондиционера в различных режимах 35 4 2 Использование таймера 36 4 3 Работа кондиционера в режиме сна 36 4 4 Замена батареек 37 5 Обслуживан...

Page 25: ... красками или легковоспламеняющимися веществами возле отверстий для забора или отвода воздуха и не распыляйте эти вещества непосредственно возле блоков A Подключайте изделие только к сетям с допустимыми напряжением и частотой Используйте соответствующие защитные устройства Не используйте медные проволочки для замены предохранителей так как это может привести к отказу оборудования и или к пожару A ...

Page 26: ...и изделие не используется в течение длительного времени электропитание следует отключить в целях безопасности и энергосбережения A Если автоматический выключатель часто срабатывает необходимо прекратить эксплуатацию изделия и обратиться к дилеру или в авторизованный сервисный центр нашей компании При повторном запуске кондиционера после длительного периода бездействия необходимо тщательно проверит...

Page 27: ...мо демонтировать для установки в другом месте или для ремонта обратитесь к нашему дилеру или в авторизованный сервисный центр В случае возникновения нештатной ситуации например при появлении запаха гари прекратите эксплуатацию изделия отключите питание и обратитесь к нашему дилеру или в авторизованный сервисный центр 1 Инструкции для пользователей ...

Page 28: ...я воздушного потока вверх вниз Для регулировки направления потока воздуха по вертикали 2 Жалюзи для направления воздушного потока влево вправо Для регулировки направления потока воздуха по горизонтали 3 Экран 4 Решетка воздухозаборника 5 Нижняя панель 6 Панель управления 7 Отверстие для выпуска воздуха 2 Наименования компонентов и их функции ...

Page 29: ...ь При выключении кондиционера когда он работает в режиме охлаждения или осушения подача воздуха не прекратится сразу же поскольку кондиционер должен выполнить операции необходимые для предупреждения образования плесени Верхняя поворотная шторка задержится на 30 секунд а затем автоматически закроется Функциональные возможности и внешний вид зависят от конкретной модели Все цифровые данные предостав...

Page 30: ...тура будет уменьшаться на 1 С Самая низкая температура составляет 16 С 6 Кнопка Fan Speed Скорость Вентилятора Используйте эту кнопку чтобы установить предпочтительную скорость потока воздуха Low Низкая Middle Средняя High Высокая 7 Кнопка Swing Поворот жалюзи Эта кнопка позволяет отрегулировать положение жалюзи по вертикали естественный поток периодическое движение вверх вниз или фиксированное на...

Page 31: ... экран дисплея показывает только функциональный режим и статус выбранной вами операции Когда температура в помещении равна или ниже 10 C функция осушения не работает Когда температура в помещении равна или ниже заданной температуры кондиционер прекращает работу на некоторое время для экономии энергии Кондиционер имеет функцию автоматического размораживания Во время размораживания на дисплее мигает...

Page 32: ...ьный электрообогреватель 4 Индикатор блокировки клавиатуры 5 Индикатор заданной температуры в помещении кода неисправности 6 Индикатор высокой скорости 7 Индикатор поворота жалюзи 8 Индикатор средней скорости 9 Индикатор низкой скорости 10 Индикатор работы в режиме вентилятора 11 Индикатор таймера 12 Индикатор работы в автоматическом режиме 13 Индикатор работы в режиме охлаждения 2 Наименования ко...

Page 33: ...ет работу на некоторое время для экономии энергии Кондиционер имеет функцию автоматического размораживания Во время размораживания на дисплее мигает индикатор работы в режиме обогрева Кондиционер с тепловым насосом имеет дополнительную функцию обогрева которая автоматически включает или выключает электрообогреватель в зависимости температуры в помещении для достижения наиболее комфортных условий Е...

Page 34: ...пку Fan Speed Скорость Вентилятора установите желаемую скорость потока воздуха В режиме осушения вентилятор работает на низкой скорости 5 Нажмите кнопку On Off Вкл Выкл еще раз чтобы прекратить работу Если включить кондиционер сразу после его выключения сработает система защиты которая автоматически задерживает запуск на 3 минуты C Примечание Выберите направление потока воздуха по вертикали и гори...

Page 35: ... 1 Индикатор скорости вентилятора Отображает заданную скорость потока воздуха 2 Индикатор режима сна Указывает время работы в режиме сна 3 Индикатор режима турбо Этот индикатор отображается при работе в режиме турбо 4 Индикатор воздушного потока Отображает выбранный режим работы жалюзи 5 Индикатор блокировки клавиатуры 6 Кнопки Temp Температура Эти кнопки используются для установки температуры в п...

Page 36: ...ндикатор периодическое движение вверх вниз отображается индикатор или фиксированное направление отображается индикатор Используя кнопку Air Flow Воздушный Поток выберите направление воздушного потока в горизонтальном правлении жалюзи может периодически двигаться влево вправо или оставаться в фиксированном положении В режиме Dry Осушение автоматически устанавливается фиксированное направление возду...

Page 37: ...аждый час Отображаемые цифры указывают время оставшееся до момента выключения Установка времени включения Если установить время включения кондиционер автоматически запустится в заданный момент времени 1 Если нажать кнопку Timer Таймер в режиме ожидания кондиционер переключится в режим включения по сигналу таймера 2 Периодически нажимая кнопку Timer Таймер можно установить необходимое время включен...

Page 38: ...4 4 Замена батареек Когда сигнал от пульта ослабляется настолько что внутренний блок не может принимать его должным образом или индикация на дисплее становится тусклой сдвиньте заднюю крышку и замените две батарейки новыми При установке новых батареек соблюдайте полярность Новые батарейки должны быть такого же типа как и заменяемые Если пульт не используется в течение длительного времени выньте ба...

Page 39: ...Очистка элемента воздушного фильтра Чтобы очистить фильтр аккуратно похлопайте его или используйте пылесос Если фильтр загрязнен очень сильно можно использовать небольшое количество нейтрального моющего средства После очистки высушите фильтр на воздухе и установите его на место C Примечание Чтобы избежать деформации элемента воздушного фильтра не подвергайте его воздействию прямых солнечных лучей ...

Page 40: ... кабель питания и провод заземления находятся в надлежащем состоянии 4 Проверьте дренажные линии на отсутствие перегибов приподнятых концов или закупорки 5 Перед началом эксплуатации изделия убедитесь что элемент воздушного фильтра установлен должным образом Если кондиционер будет запущен без воздушного фильтра пыль и посторонние частицы могут снизить производительность или вызвать повреждение кон...

Page 41: ...являться хлопающие звуки Это происходит потому что некоторые части поверхностей расширяются за счет изменения температуры что приводит к трению этих частей Это не является признаком неисправности оборудования Охлаждение отличное В режиме охлаждения из отверстия для выпуска воздуха иногда выходит туман Это явление возникает потому что воздух в помещении быстро охлаждается в результате того что темп...

Page 42: ...гим мощным источником света он скорее всего не будет работать надлежащим образом Чтобы устранить эту проблему закройте окна шторами или уменьшите уровень искусственного освещения в помещении 2 Удостоверьтесь что приемник находится в зоне приема Проверьте также нет ли препятствий для распространения сигналов 3 Проверьте напряжение батареек в пульте дистанционного управления и замените их если они р...

Page 43: ......

Page 44: ...Изделие изготовлено компанией Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey Стамбул Турция ...

Page 45: ...www beko com ...