10.3.2 Functional test
Illustration
Description / explanation
Press the TEST button for 2 … 5 seconds.
0
The red ALARM LED is off.
0
The green VALVE LED is on.
0
The green POWER LED is on.
0
The valve opens and condensate is drained.
10.3.3 Visual inspection
During the visual inspection of the
BEKOMAT
®
, inspect all components for mechanical damage and corrosion. Replace
damaged components immediately.
10.3.4 Leakage test
The leakage test is a non-destructive test method and is used to prove leak tightness in vacuum and overpressure
systems. The leakage test can be carried out in different ways.
BEKO
TECHNOLOGIES provides no recommendations
for selecting a testing process. The operating company of the pressurised system is responsible for the selection and
specification of the test method to be used, which should be executed in corresponding to with valid standards and
regulations (e.g. DIN EN 1779).
Original installation and operation manual
BEKOMAT
®
14i / 14i CO / 14i CO PN25
57 | 76