32 / 120 EN
Split-type room air conditioner / Installation Manual
W
A
B
D
Air inlet
Air inlet
Air outlet
W
A
B
D
Fig. 6.5
Outdoor unit dimensions (mm/in)
Mounting dimensions
W x H x D
Distance A (mm/in)
Distance B (mm/in)
681x434x285 (26.8”x17”x11.2”)
460 (18.10”)
292 (11.49”)
700x550x270 (27.5”x21.6”x10.62”)
450 (17.7”)
260 (10.24”)
780x540x250 (30.7”x21.25”x9.85”)
549 (21.6”)
276 (10.85”)
845x700x320 (33.25”x27.5”x12.6”)
560 (22”)
335 (13.2”)
810x558x310 (31.9”x22”x12.2”)
549 (21.6”)
325 (12.8”)
700x550x275 (27.5”x21.6”x10.82”)
450 (17.7”)
260 (10.24”)
770x555x300 (30.3”x21.85”x11.81”)
487 (19.2”)
298 (11.73”)
800x554x333 (31.5”x21.8”x13.1”)
514 (20.24”)
340 (13.39”)
845x702x363 (33.25”x27.63”x14.29”)
540 (21.26”)
350 (13.8”)
900x860x315 (35.4”x33.85”x12.4”)
590 (23.2”)
333 (13.1”)
945x810x395 (37.2”x31.9”x15.55”)
640 (25.2”)
405 (15.95”)
946x810x420 (37.21”x31.9”x16.53”)
673 (26.5”)
403 (15.87”)
946x810x410 (37.21”x31.9”x16.14”)
673 (26.5”)
403 (15.87”)
If you will install the unit on the ground or on a concrete mounting platform, do the following:
1. Mark the positions for four expansion bolts based on dimensions in the Unit Mounting Dimensions
chart.
6
Outdoor unit installation
Summary of Contents for BEHPI 090
Page 2: ......
Page 52: ...52 120 EN Do not C 11 ...
Page 60: ......
Page 110: ...110 120 SI ne Ob nakupu nove naprave bo prodajalec brezplačno prevzel staro napravo C 11 ...
Page 118: ......
Page 119: ......
Page 120: ...www beko com ...