1. Description
2. Operation
2.1 Initialisation
2.2 Controls
2.3 Displays
2.3.1 Display over-range
3. System Design
3.1 Power supply
3.2 Pulse
input
3.2.1 Switch contact input
3.2.2 Open collector input
3.2.3 2-wire proximity detector input
3.2.4 Magnetic pick-off input
3.2.5 Voltage pulse input
3.3 Remote reset
4. Installation
4.1 Location
4.2 EMC
4.3 Installation procedure
4.4 Scale card
5. Configuration and Calibration
5.1 Configuration structure
5.2 Accessing configuration functions
5.3 Summary of configuration functions
5.4 Rate totaliser function:
function
5.5 Input:
input
5.6 Input type:
inp
.
type
5.7 Debounce:
debounce
5.8 Display update interval:
update
5.9 Upper display:
di5p-1
5.10 Lower display:
di5p-2
5.11 Position of decimal points:
dp
5.12 Flowmeter K-factor:
factor
5.13 Total scale factor:
5cale
.
t
5.14 Rate scale factor:
5cale
.
r
5.15 Timebase:
t-ba5e
5.16 Display filter:
filter
5.17 Clip-off:
clp off
5.18 Local reset:
loc clr
5.19 Local total reset:
clr tot
5.20 Local grand total reset:
clr gtot
5.21 Grand total reset from configuration menu:
clr gtot
5.22 Define security code:
code
5.23 Reset to factory defaults:
r5et def
6. Lineariser
6.1 Flowmeter specifications
6.2 Summary of lineariser configuration
functions.
6.3 Add a segment:
add
6.4 Remove a segment:
del
6.5 Input frequency:
pul5efre
6.6 K-factors:
l-factor
6.7 Lineariser error messages
7. Configuration example
7.1 Configuration procedure
8. Maintenance
8.1 Fault finding during commissioning
8.2 Fault finding after commissioning
8.3 Servicing
8.4 Routine maintenance
8.5 Guarantee
8.6 Customer comments
9. Accessories
9.1 Scale card
9.2 Tag information
9.3 Backlight
9.4 Alarms
9.4.1 Solid state output
9.4.2 Configuration and adjustment
9.4.3 Alarm enable:
enbl
9.4.4 Type of alarm:
type
9.4.5 Setpoint adjustment:
5p1
x and
5p2
x
9.4.6 Alarm function:
hi.
lo
9.4.7 Alarm output status:
no.nc
9.4.8 Hysteresis:
h5tr
9.4.9 Alarm delay:
dela
9.4.10 Alarm silence time:
5il
9.4.11 Flash display:
fl5h
9.4.12 Access setpoint:
ac5p
9.4.13 Adjusting alarm setpoints
from totalisation mode:
9.5 Pulse Output
9.5.1
System design
9.5.2
Configuration
9.5.3
Pulse output:
pul5e op
9.5.4
Enable:
enbl
9.5.5
Pulse source:
5ource
9.5.6
Output pulse frequency:
divide
9.5.7
Output pulse width:
duration
9.5.8 Pulse
storage
9.6 4/20mA output
9.6.1
System design
9.6.2 Configuration
9.6.3 4/20mA output:
4-20op
9.6.4
Enable 4/20mA output:
Enbl
9.6.5
Select rate or total source:
4-20type
9.6.6 Display for 4mA output:
4
.
000
9.6.7 Display for 20mA output:
20
.
000
222222222222222222222222
The BA537E and BA538E are CE marked to show compliance with the European EMC Directive 2014/30/EU