Appendix
2
ETL
&
cETL
certification
for
installations in USA and Canada
A2.0 cETL Mark
For installations in the USA and Canada, the BA337E
and the BA338E Rate Totalisers have ETL and cETL
intrinsic safety and nonincendive approval, Control
Number 4008610.
Copies of the Authorisation to
Mark are available from the BEKA associates sales
office and www.beka.co.uk
A2.1 Intrinsic safety approval
The
US
and
Canadian
standards
used
for
assessment and certification of the BA337E and
BA338E are listed on the cETL Authorisation to Mark.
Installations must comply with BEKA associates
Control Drawing CI330-52, which is attached to this
appendix.
The ETL safety parameters are the same as the ATEX
and IECEx parameters, the systems shown in
sections 3 and 4 of this manual may therefore also be
used for US and Canadian installations subject to
compliance with the local codes of practice.
ETL and cETL intrinsic safety codes
CL I Div 1 Groups A, B, C, D T5 (US IS gas, Div cert)
CL II Div 1 Groups E, F, G. CL III (US IS dust, Div cert)
CL I Zone 0 AEx ia IIC T5 Ga (US IS gas, Zone cert)
Ex ia IIC T5 Ga (Canadian IS gas, Zone cert)
-40ºC
Ta
70ºC
A2.2 Nonincendive approval
The BA337E and BA338E Rate Totalisers also have
ETL nonincendive approval allowing installation in
Division 2 hazardous (classified) locations without
the need for Zener barriers or galvanic isolators.
Installations must comply with BEKA associates
Control Drawing CI330-53, which is attached to this
appendix, and with the local codes of practice.
ETL and cETL nonincendive codes US & Canada
CL I Div 2 Groups A, B, C, D T5
CL II Div 2 Groups F, G CL III Div 2
-40ºC
Ta
70ºC
49
Summary of Contents for BA337E
Page 4: ...4 ...
Page 22: ...22 ...
Page 23: ...23 ...
Page 30: ...30 ...
Page 41: ...41 ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 ...
Page 55: ...55 ...
Page 56: ...56 ...
Page 57: ...57 ...
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ...60 ...
Page 61: ...61 ...