13
User manual
DMX Tool
7)
Load points: the number of load points should not be less than the number of lamp test
addresses (usually set to 512).
8)
Manual test: After the coding is successful, click the manual test switch and select the
manual test + or manual test button to manually check the coding address of the lamp.
9)
Advanced Settings: Select the chip model, click the Advanced Settings button, cut to the
interface in Figure 4.
Write RGB parameters through the encoder: can be set after
power-on, RGB one of three port output gray combinations,
greatly improving project flexibility, the user can set a single
power on the light gray jumpsuit. If the parameters have not been
written, the factory default boot + colorful gradual change.
Field: default value 3.
Status: self-check color or latest image.
Parameters: field 3 default value, power-on gray value (0~255),
press the
“write parameters”
button to set the lamp to light color.
Current: in the R current, G current, B current, the current button
adjust the different current value (different chip model adjustable
current range), press the "write current" button, to change the
value current of the corresponding lamp channel.
Figure 4
2.5
Program
1)
SD card format, use "LEDEasy" design template file (Cfg/Dat) (see software specification
for detailed operation). Copy design file to SD card. Insert the SD card into the encoder,
click the
“program”
button on the main interface after power on, play mode interface to
play, as shown in figure 5.
Insert the SD card, the corresponding icon will appear on the
playback interface, remove the SD card, the icon will disappear.
Folder Name: Displays the name of the file being read.
Number of files displays the total number of files on the SD card.
Figure 5