background image

Page  7

N O T E S

1

1

4

 mm

4

0

 mm

58 mm

SGM595
autosetting

ON

78  mm

Cable  Gland    PG13,5

Opening of the Cover.
With  the  help  of  a  screwdriver
to  turn  counterclockwise  for  a
quarter  of  turn

Closeof the Cover.
With  the  help  of  a  screwdriver
to  turn  counterclockwise  for  a
quarter  of  turn

1)  Put  out  all  free  flames.
2)  Close  the  main  gas  tap  or  the  LPG  cylinder  tap.
3)  Do  not  turn  any  lights  on  or  off;  do  not  turn  on  any  electrical  device  or  appliance.
4)  Open  windows  and  doors  in  order  to  increase  ventilation.

If  the  alarm  stops,  its  cause  must  be  found  and  the  relevant  consequent  measures  taken.
If  the  alarm  continues  and  the  cause  of  gas  presence  cannot  be  found  or  removed,  abandon  the  building
and  call  the  emergency  services  when  outside  (fire  department,  distributors,  etc.)
IMPORTANT:  The  operation  test  should  not  be  carried  out  with  the  gas  tap  as  this  does  not  guarantee  a
sufficient  concentration  to  activate  the  general  alarm.

Warning  !!

If  you  have  the  following  symptoms:  vomiting,  sleepiness,  or  else,  go  to  the  closest  first  aid
station  and  inform  the  operators  that  you  could  have  been  poisoned  by  Carbon  Monoxide,  or
by  an  excess  or  deficiency  of  oxygen

WARNING!  Actions  to  be  taken  in  case  of

alarm

Measurements  and  dimensions

Summary of Contents for SGM595

Page 1: ...ith one of BEINAT s industrial type Control Units detects the presence of esplosive gas such as Methane LPG Hydrogen The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected to it but also allows execution of a self diagnosis and therefore an AUTOMATIC CALIBRATION in order to always have the maximum detection accuracy The self calibration means...

Page 2: ... gas by issuing it from a pre calibrated testing aerosol Important The test of operation and eventually offset cancellation must be performed at least once a year by a qualified technician CHECK the integrity of the unit after having removed it from the box Check that the data written on the box correspond to the type of gas used When doing the electrical connections follow the drawing closely Any...

Page 3: ... operation of the control unit by spraying a suitable test gas at the base of the probes connected until the alarm condition is reached At least once a year make a more accurate check by a specialist technician Disabling the detector must be carried out by qualified personnel The position of the probe is a crucial factor for a gas detection unit correct functioning In order to obtain the maximum r...

Page 4: ...The probe detects an anomaly FAULT 1 2 3 4 5 6 C NO C NO C NO Fault Relay Pre Allarme Relay Pre Allarme Relay Optional Relay Card CARD03 Linear Output 4 20 mA 100 20 100 20 SELECTION OF THE OPERATING RANGE The SGM595 Conventional Probes NOT SUITABLE IN ATEX ZONE LEAVE THE FACTORY WITH A DEFAULT OPERATING RANGE VALUE SET AT 20 OF THE LEL To select the operation range to 100 LEL you need to move the...

Page 5: ...mise the safety of the survey If the device does not start up Check that the 12 24 Vdc power is present and that positive and negative polarity has not been inverted If the Fault LED lights up Check that the cables are connected according to the drawing and that the wire isolation sheath has not been pinched Check the voltage at the terminals 1 2 It must be higher than 10 80 Vdc and lesser than 26...

Page 6: ...nce and gas sensor replacement Detectiondiagrams data ppm 0 50 100 150 200 250 300 6 7 Toxic Gas Detection diagram 0 4 5 10 15 20 7 2 20 m A Linear 5 Zona Avaria 9 3 12 14 6 17 3 Explosive Gas Detection diagram 0 4 8 12 16 20 0 4 5 10 15 20 7 2 10 4 13 6 16 8 20 m A Linear 5 L I E Zona Avaria The installation of the SGM595 probe its ordinary and extraordinary maintenance and its out of service rem...

Page 7: ... stops its cause must be found and the relevant consequent measures taken If the alarm continues and the cause of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department distributors etc IMPORTANT The operation test should not be carried out with the gas tap as this does not guarantee a sufficient concentration to activate the gener...

Page 8: ...shall be excluded from the warranty BEINAT S r l is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicab...