WARNING
Before  connecting  to  the  mains  power,  ensure  the  voltage  is  correct.  Carefully  follow  the  instructions  and  the
connections  according  to  Regulations  in  force,  keeping  in  mind  that  the  signal  cables  should  be  laid  separate
from  the  power  cables

Electrical    connections

3    2   1

1
2
3
4
5
6
7

SGI595

1
2
3
4
5
6
7

1
2
3
4
5
6
7

1
2
3
4
5
6
7

ON

1  2  3  4 5  6

Led  ON

100%              20%

3    2    1

R

Power  Supply
    12÷24  V.

TS1008  connection

{

FUNCTIONING  OF  LED

The  integrated LED  on  the  sonde has  a  threefold
function:

1)  Green  LED.  Normal  operation;  In  waiting
phase,  the  LED  flashes.
2)  Red  LED.  State  of  alarm;  The  frequency  of
light  changes  according  to the  percentage of  gas
monitored.
3)Led  yellow.  The  probe  detects  an  anomaly,
FAULT

1     2     3    4     5    6

C

NO

C

NO

C

NO

Fault  Relay

Pre-Allarme
Relay

Pre-Allarme
Relay

Optional  Relay  Card     

CARD03

    Linear  Output  4-20  mA

100%              20%

100%
20%

SELECTION  OF  THE  OPERATING
RANGE

The  SGM595  Conventional  Probes,
NOT  SUITABLE  IN    ATEX  ZONE,

LEAVE

 

THE

 

FACTORY

 

WITH

 

A

 

DEFAULT

O

PERATING

 R

ANGE

 

VALUE

 

SET

 

AT

 20% 

OF

THE

  LEL.

To  select  the  operation  range  to
100%  LEL  you  need  to  move  the
jumper  between  the  central  and  the
left  pole.

Warning  !!

Before  to  do  this,  it  may  want  to
check  the  operation  range  of  the
control  unit.

Furthermore,  this  operation  must
be  carried  out  by  an  authorized
and  /  or  trained  technician.

OPTIONAL CARD03 BOARD INSERTION

B ef ore  inse rting   the   Op e n  Colle ctor
CARD03  board,  switch  off  the  power  to
the  probe.

Insert  the  board  according  to  the  drawing
keeping  the  terminal  block  on  the  left.
All  relays  are  voltage  free.
Contact  capacity  1A  30VDC    SELV

Summary of Contents for SGM595

Page 1: ...ith one of BEINAT s industrial type Control Units detects the presence of esplosive gas such as Methane LPG Hydrogen The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected to it but also allows execution of a self diagnosis and therefore an AUTOMATIC CALIBRATION in order to always have the maximum detection accuracy The self calibration means...

Page 2: ... gas by issuing it from a pre calibrated testing aerosol Important The test of operation and eventually offset cancellation must be performed at least once a year by a qualified technician CHECK the integrity of the unit after having removed it from the box Check that the data written on the box correspond to the type of gas used When doing the electrical connections follow the drawing closely Any...

Page 3: ... operation of the control unit by spraying a suitable test gas at the base of the probes connected until the alarm condition is reached At least once a year make a more accurate check by a specialist technician Disabling the detector must be carried out by qualified personnel The position of the probe is a crucial factor for a gas detection unit correct functioning In order to obtain the maximum r...

Page 4: ...The probe detects an anomaly FAULT 1 2 3 4 5 6 C NO C NO C NO Fault Relay Pre Allarme Relay Pre Allarme Relay Optional Relay Card CARD03 Linear Output 4 20 mA 100 20 100 20 SELECTION OF THE OPERATING RANGE The SGM595 Conventional Probes NOT SUITABLE IN ATEX ZONE LEAVE THE FACTORY WITH A DEFAULT OPERATING RANGE VALUE SET AT 20 OF THE LEL To select the operation range to 100 LEL you need to move the...

Page 5: ...mise the safety of the survey If the device does not start up Check that the 12 24 Vdc power is present and that positive and negative polarity has not been inverted If the Fault LED lights up Check that the cables are connected according to the drawing and that the wire isolation sheath has not been pinched Check the voltage at the terminals 1 2 It must be higher than 10 80 Vdc and lesser than 26...

Page 6: ...nce and gas sensor replacement Detectiondiagrams data ppm 0 50 100 150 200 250 300 6 7 Toxic Gas Detection diagram 0 4 5 10 15 20 7 2 20 m A Linear 5 Zona Avaria 9 3 12 14 6 17 3 Explosive Gas Detection diagram 0 4 8 12 16 20 0 4 5 10 15 20 7 2 10 4 13 6 16 8 20 m A Linear 5 L I E Zona Avaria The installation of the SGM595 probe its ordinary and extraordinary maintenance and its out of service rem...

Page 7: ... stops its cause must be found and the relevant consequent measures taken If the alarm continues and the cause of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department distributors etc IMPORTANT The operation test should not be carried out with the gas tap as this does not guarantee a sufficient concentration to activate the gener...

Page 8: ...shall be excluded from the warranty BEINAT S r l is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicab...

Reviews: