Button  functions

MT  On/Off  button.
To  turn  the  instrument  on  or  off,  press  the   

 

 

    button  for  5  seconds

PRESSURE  GAUGE  Function.
The  instrument  can  display  2  scales:  one  in  mmH

2

O  and  the  other  in  mbar,

Keep  the  “Press”  button  pressed  for  2"  to  access  the  Pressure  Gauge  function.
When  the  instrument  is  switched  on  it  positions  itself  on  the  999  mmH

2

O  scale.

Press  the  “Press”  button  again  for  2"  to  access  the  150  mbar  scale.

THERMOMETER  Function.
Press  the  “Temp”  button  for  2"  to  access  the  Thermometer  function.  The  instrument  turns  on  and  starts
to  measure  the  room  temperature.
Lift the probe up, by turning it, for maximum reading precision. The measurement scale is -50 °C to +100
°C
.

View  from  above

Pressure             Gas

View  from  below

Battery  charger

Temperature   Probe
90°  Rotation

Product  data  label

Press+                   Press -

°C

Press               Temp

MT

Components and Commands

Summary of Contents for MT

Page 1: ... this an indispensable tool for testing and control of heating systems It is calibrated with sophisticated testing machines so its measurement is very precise and is also calibrated example for Pressure of gas mains Gas pressure to burner nozzles Flue efficiency Portable Micromanometer Firmw are Versione 3 1 User guide Firmware Version 1 0 Conformity EMC EN50270 Thank you for choosing the BEINAT S...

Page 2: ...oming from the appliance or power supply optional accessory Immediately turn off the detector disconnect the power supply from the mains if connected to charge the battery and send to the nearest Service Centre Do not try to dismantle the appliance Contact with internal components of the detector can cause injury In the event of faults the product should only be repaired by qualified personnel If ...

Page 3: ...sitions itself on the 999 mmH2 O scale Press the Press button again for 2 to access the 150 mbar scale THERMOMETER Function Press the Temp button for 2 to access the Thermometer function The instrument turns on and starts to measure the room temperature Lift the probe up by turning it for maximum reading precision The measurement scale is 50 C to 100 C View from above Pressure Gas View from below ...

Page 4: ...the instrument to the pressure or depression source for measurement the instrument measures both positive and negative pressure PRESSURE GAUGE Function Press the button and then the Press function button PRESSURE GAUGE Function Press the Press button to access the Pressure Gauge function with its mmH2 O scale When the instrument is switched on it positions itself on the 999 mmH2 O scale If the pre...

Page 5: ...f recharge can give false measurements THERMOMETER FUNCTION Press the button followed by the Temp function button THERMOMETER Function Press the Temp button to access the thermometer function When the instrument is turned on it starts to read the room temperature Lift the probe up by turning it for maximum reading precision SWITCH OFF Press the OFF button for 5 seconds Problems and Solutions Therm...

Page 6: ...hose natural validity is ONE YEAR must be carried out by authorised personnel with equipment in compliance with standards Calibration Information Pressure and Temperature Rechargeable Battery This device is equipped with a 3 7V rechargeable LITHIUM POLYMER battery To recharge the battery it should be connected to the PC using a USB cable or you can purchase a 230V recharging cable separately When ...

Page 7: ...asurements taken with batteries in need of recharge can give false measurements CERTIFICATE OF CALIBRATION pressure gauge MT Instrument Digital pressure gauge MT Version V 1 0 Digital pressure gauge 200mmH2O 1529 57mmH2O PRESSURE Sample instrument Serial number Measurement range Uncertainty Resolution DRUCK DPI 530 4bar 0745 99 09 0 100 mbar 0 1 F S 1 mbar 100Pa Measurements in pressure Type measu...

Page 8: ... is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electri...