BEINAT GS913- V.6 Manual Download Page 3

35 mm

5

0

 mm

Page  3

110 mm

5

0

 mm

ON

Fault

Alarm

GS913

1) MAINS connected indication LED (ON).
2) FAULT indication LED. If this LED turns on, it means that the gas detection semiconductor sensor is not working
efficiently and must be replaced by an authorized service center.
3) ALARM indication LED. This LED turns on when room gas concentration exceeds the danger level.
4) Jumper to select the relay functioning mode. By closing the two poles, the relay will be set to impulse functioning.
That is, when the alarm is triggered, the relay will close the C and NA contacts for about 90 seconds, and then will
reopen them. This is needed to prevent damaging some types of manual reset solenoid valve coils. By opening the two
poles, the relay will be set to continuous functioning.
5) Semiconductor sensor for Methane or LPG explosive gas detection.
6) TEST button. This button is used to simulate a gas leak, after installation.
7) Trimmer of setting. It must be touched only from technical competent
8) Identification label, registration number and manufacturing year, located under the ABS small dome.

Dimensions

5

4

6

7

1

  2

   

3

  4

   

5

  6

Y

e

a

r

2

0

1

0

1)

 Power

2) 

Fault

3) 

Alarm

8

Output  Segnale  di
fault    max  0,05  mA

Components and commands

Summary of Contents for GS913- V.6

Page 1: ...prestige that have always made BEINAT S r l stand out from its competitors together with the concept of home fitness comes the household gas detector GS913 detects through the Semiconductor the presence of explosive gas such as LPG Gas detection The detector is tested and calibrated to 10 of L E L Through the built in relay the GS913 can activate solenoid valves sirens and any other device alarm A...

Page 2: ... cloth dipped in thinners alcohol and chemical detergents Power supply 12VDC 10 Power consumption 1W 12V Range of relay contact switching 10A 250V resistive 5A 30Vdc resistive Explosive gas sensor Semiconductor Types of gas detected LPG Gas Explosion Alarm Threshold At 10 of L E L Explosive gas detector alarm threshold Immediate Sensor s faults detected by Fault Circuit Interruption short circuit ...

Page 3: ...m is triggered the relay will close the C and NA contacts for about 90 seconds and then will reopen them This is needed to prevent damaging some types of manual reset solenoid valve coils By opening the two poles the relay will be set to continuous functioning 5 Semiconductor sensor for Methane or LPG explosive gas detection 6 TEST button This button is used to simulate a gas leak after installati...

Page 4: ...te the general test issue gas from a pre calibrated aerosol within 20 of L E L Testing using a common cigarette lighter could damage the sensor The position of the detector is a crucial factor for its correct functioning during gas detection In order to obtain the maximum results from a device and minimize the probability of false alarms it is recommended to follow this scheme and keep in mind the...

Page 5: ...n of the spaces and the elimination of combustion products are described in the UNI norms according to ART 3 LAW 1083 71 and relevant legal provisions Before calling a technician WARNING Actions to be taken in case of alarm Gas 1 Put out all free flames 2 Close the main gas tap or the LPG cylinder tap 3 Do not turn any lights on or off do not turn on any electrical device or appliance 4 Open windo...

Page 6: ...Contact capacity 5A 24 VDC SELV Jumper for Relay working Mode 1 With the Jumper opened the relay works in continuos Mode 2 With the Jumper closed the relay works in pulsed Mode The pulse duration is 5 seconds WARNING The relay is voltage free Contact capacity 5A 24 VDC SELV One detector with 12V normally closed valve Power Supply 12 VDC Output Segnale di fault max 0 05 mA 1 2 3 4 5 6 N C C NO Rela...

Page 7: ... more detectors with 12VDC normally closed valve Solenoid Valve WARNING The relay is voltage free Contact capacity 5A 24 VDC SELV One o detector with 12V normally open valve 1 2 3 4 5 6 N C C NO Power Supply 12 VDC Solenoid Valve Output Segnale di fault max 0 05 mA 1 2 3 4 5 1 2 3 4 5 Power Supply 12 VDC ...

Page 8: ...le for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and elec...

Reviews: