Page 2
Technical Specifications
CHECK the integrity of the probe after having removed it from the box.
Check that the data written on the box correspond to the type of gas used.
When doing the electrical connections, follow the drawing closely.
Any use of the detector for purposes other than the intended one is considered improper, and as a result of
which BEINAT S.r.l. therefore disclaims any responsibility for possible damages caused to people, animals
or objects.
INSTALLATION
When performing the installation, please remind that if you pierce the GS913 container, it will lose its properties
and its conformity to REGULATIONS.
TERMS and EXPECTATIONS: The installation of the GS913 detector, its ordinary and extraordinary
maintenance, and its out of service removal at the end of the functional life guaranteed by the manufacturer,
must be carried out by authorized and/or specialized personnel.
Do not allow it to become wet.
The detector can be seriously damaged when immersed in water. Remember that the probe has an IP30
protection degree.
Do not drop it.
Heavy knocks or falls during transportation or installation can damage the appliance.
Avoid abrupt temperature fluctuations.
Sudden temperature variations can cause condensation and the probe could work poorly.
Cleaning
Never clean the device with chemical products. If necessary, wash with a moist cloth.
Absolutely avoid using any cloth dipped in thinners, alcohol and chemical detergents.
Power supply ............................................................................................................ 12VDC +/- 10%
Power consumption ............................................................................................................... 1W @ 12V
Range of relay contact switching ........................................................10A 250V resistive - 5A 30Vdc resistive
Explosive gas sensor ....................................................................................................... Semiconductor
Types of gas detected ............................................................................................................ LPG Gas
Explosion Alarm Threshold .............................................................................................. At 10% of L.E.L.
Explosive gas detector alarm threshold ...................................................................................... Immediate
Sensor’s faults detected by Fault Circuit .................................................... Interruption, short circuit, or wear
Audible and visual signal alarm by ............................................................................... LED diode and buzzer
Test Phase Duration ............................................................................................................. 60 seconds
Functioning Temperature ...................................................................................................... -10 +40°C
Functioning Humidity ......................................................................................... 0÷90% RH non condensed
External degree of protection ......................................................................................................... IP30
Mounting ................................................................................................................ External wall mount
Body material ...................................................................................................... ABS self-extinguishing
Dimensions ......................................................................................................................... 110x50x35
Electromagnetic Compatibility “CE Reference Norms “ ................................................................... EN 50270
The installation of the GS913 detector, its ordinary and extraordinary maintenance, and its out of service
removal at the end of the functional life guaranteed by the manufacturer, must be carried out by authorized
and/or specialized personnel.
The SEMICONDUCTOR technology sensor duration is guaranteed for 6 years (in clean air).
The detector’s functioning temperature ranges from -10°C to + 40°C.
WARNING!
The SEMICONDUCTOR probe does not tolerate a gas detection exceeding 100% of L.E.L., with consequent natural death
of the sensor.
Each immediate puff of gas that exceeds 100% of L.E.L. takes away months of life from the sensor.
The detector must be tested by simulating the presence of gas by issuing it from a pre-calibrated testing aerosol.
A common cigarette lighter near the sensor does not guarantee excellent functioning.
Precautions