background image

 

 

Chapter 1 Overview 

1. Description   

RC902- FE4E1, 10/100M auto-sensing Ethernet interface converter of Ethernet 

to 4E1, is one product of RC series converters made by Beijing Raisecom Science & 
Technology Co. ltd. It provides a simple solution to enable Ethernet access by using 4 
E1 links for signal transmissions.   

RC902-FE4E1 is modular device. It can provide central SNMP management 

solution, when it is plugged in RC002-16 that is 16 slot chassis. 

It can support remote management when it works in pair with RC901-FE4E1. 

 

2. Specification 

1

E1 interface

 

  RJ-45 (120 

, balanced) 

      Bit rate: 2048Kbps±50ppm 

Line code: HDB3 
Compliance:  ITU-T G.703, 

ITU-T G.823 

Other features:   
      Real-time BER detecting and E1links auto protection auto-reset   
 

Resistance for drift of 512UI, the ability of counteraction of jitter and drift   

       Selectable BER threshold of link auto-reset: 10

-6 

(default) or 10

-5 

 

 

 

2

Fast Ethernet interface

 

Interface: RJ-45, cat5/cat5e cables available, supports link distance up to 100m 
  Bit rate: selectable, Auto-sensing 10M/100Mbps or manual configuration   
  Duplex type: Full/Half duplex auto-negotiation or manual configuration 

Compliance: IEEE 802.3

IEEE 802.3u 

    Other features: 
          Supports maximum frame size up to 1536 bytes 

Supports IEEE 802.3d Spanning Tree, 802.1q VLAN 

          Supports 1K MAC address table, address filtering, improve efficiency of 
E1 link 
          Supports Auto-MDI/MIDX auto-negotiation 

Supports Link Fault Pass-though (LFP) 
Provides 64Mbit SDRAM for reducing the network congestion. 

 

3. Features 

 

3

Summary of Contents for RC902-FE4E1

Page 1: ...RC902 FE4E1 fast Ethernet to 4 E1converter User guide Beijing Raisecom Science Technology Co ltd...

Page 2: ...Content Chapter 1 Overview 3 Chapter 2 Connection features 6 Chapter 3 Installation and test 7 Chapter 4 Introduction of DIP Switch 8 Chapter 5 Troubleshooting 12 2...

Page 3: ...3 Other features Real time BER detecting and E1links auto protection auto reset Resistance for drift of 512UI the ability of counteraction of jitter and drift Selectable BER threshold of link auto res...

Page 4: ...king means the two converters have no alarm occurs in E1 link 3 Fault Pass Through RC901 FE4E1 provides Fault Pass Through FPT for special requirements e g which need Spanning Tree superior switch net...

Page 5: ...If A link has been connected A link is green Other link indicators are off Then B link is connected B link is green automatically Green means that normal status And so on A B C D four E1 links are all...

Page 6: ...Switch and NIC can be connected by both straight line and cross line If UTP port is set to define fixed speed or Full duplex mode RC901 FE4E1 will lose this function The feature of that RC902 FE4E1 co...

Page 7: ...er to the table and figure below when use the balanced interface 120 PIN No 1 2 3 4 5 6 7 8 Label TD TD Not used Not used RD RD Not used Not used Signification Output Output Input Input 120 balanced i...

Page 8: ...more than 10 6 4bit choice of compatibility 5bit reserved 6bit configuration of Eth 7bit configuration of Eth Shown as table and figure below 8bit fault pass Disable Enable Remote loopback If any of E...

Page 9: ...interface Sniffer is for diagnosing Ethernet interface Note Ethernet data also loop back during local loop back it easy to make broadcast storm which occurred in Ethernet switches connected with loca...

Page 10: ...le auto sensing function force port to 10M half duplex 10M half duplex will be obtained 10M Full duplex port Disable auto sensing function force port to 10M full duplex 10M full duplex will be obtaine...

Page 11: ...function for special requirements In case of any E1 link was out of work RC901 FE4E1 could transmit the Ethernet packets in the other available E1 links automatically until all E1 links were not avai...

Page 12: ...rd Please check the fault pass function is Enable or Disable If it is Enable it can make Ethernet port to close 3 E1 line indicator alarm If there is E1 line alarm please find the fault reason accordi...