6.3.8
The Emergency Stop Switch
The QTERM-P40 has an optional Emergency Stop Switch
(E-stop) that can be used for triggering some external event
or device. This switch is a push-once, twist to reset, mush-
room shaped switch mounted on the front lower left side of
the terminal.
Connection to the E-stop switch is made through the inter-
face connectors on the back of the QTERM-P40. The DB9
connector has leads for the common and normally closed
switch contacts. The 10-pin terminal strip has leads for the
common, normally closed and normally open switch con-
tacts (see Table 6-1 for pin designations). This switch is
rated for a maximum of 1 amp at 30VDC.
6.4
QTERM-P40 Specifications
Table 6-3 lists various specifications for the QTERM-P40.
Note that all components of the QTERM-P40, other than
the display, will operate over the industrial temperature
range of -40 to 85 °C. Table 6-4 lists current consumption
of the various versions of the QTERM-P40.
Table 6-3: Environmental and Power
Specifications.
Parameter
Limits
Operating Temperature Range
(except for display)
-40 to 85°C
Standard/Backlit Display usable
temperature range
-10 to 60°C
Storage temperature,
all components
-40 to 85°C
Maximum humidity
range, all components
0 to 95%,
non-condensing
Operating voltage range,
with regulator disabled
4.8 to 5.5 volts
Operating voltage range,
with regulator enabled
5.5 to 24 volts
Table 6-4: QTERM-P40 Current
Consumption (mA).
Version
Ireg
Active
Ireg
Disp Off
EIA-232 version
5-volt Buffered
version
EIA-422 version
Add for backlight
(when on)
Add for each LED on
keypad (when on)
Add for regulator
Add for bar code wand
(w/o wand)
25
22
22
150
4
1
3
15
12
12
-
4
1
3