Setup
12
Beijer Electronics AB, MA00645
The table below presents an overview of the function keys that can be used in
C-Key16.
Function keys
Function
F16 + F1
Sets the station number to 1. Default setting.
F16 + F2
Sets the station number to 2.
F16 + F3
Sets the station number to 3.
F16 + F4
Sets the station number to 4.
F16 + F9
Sets the baud rate to 9,600.
F16 + F10
Sets the baud rate to 19,200.
F16 + F11
Sets the baud rate to 38,400. Default setting.
F16 + F13
Sets RS422 as the communication port used.
F16 + F14
Sets RS232C as the communication port used. Default setting.
F16 + F15
Sets RS485 as the communication port used.
F16 + F7
Enables the C-Key16 connected to the operator terminal to pass
through messages to other stations in the RS485 network.
F16 + F8
Clears F16 + F7, and disables pass through. Default setting.
F1 + F2
Prepares for loading of system program.*
F1 + F9
Start of self test.*
* Functions intended for troubleshooting and updating, normally not used.
Note!
If only one C-Key16 is used, pass through must not be enabled (the LED L7 must
not light up in green when the power is turned on).
Summary of Contents for C-Key16
Page 1: ...C Key16 Manual MA00645 2002 11 English...
Page 21: ...Drawings Beijer Electronics AB MA00645 21 7 Drawings Outline drawing...
Page 22: ...Drawings 22 Beijer Electronics AB MA00645 C Key16 installation...
Page 23: ...Drawings Beijer Electronics AB MA00645 23 Connection drawing...
Page 24: ...Drawings 24 Beijer Electronics AB MA00645 CAB8...
Page 25: ...Drawings Beijer Electronics AB MA00645 25 CAB21...
Page 26: ...Drawings 26 Beijer Electronics AB MA00645 Text strips...