Error indication
20
Beijer Electronics AB, MA00645
6
Error indication
Errors in the extended keyboard are indicated by a LED, or a combination of
LEDs, shining in solid red. In addition, LED L16 will flash in red.
To restart the extended keyboard after an error, press function key F16.
Indicating LED
Error
number
Error name
Steps to take
All LEDs
E_STACK_OVERRIDE
If the error occurs
repeatedly, contact
Beijer Electronics.
L8
00000001 BUFFEROVERFLOW1
L7
00000010 BUFFEROVERFLOW2
L7 + L8
00000011 STX_MISSING
L6
00000100 OUTOFTIMERS
L6 + L8
00000101 FLASHERROR1
L6 + L7
00000110 FLASHERROR2
L6 + L7 + L8
00000111 FLASHERROR3
L5
00001000 FLASHERROR4
L5 + L8
00001001 FLASHERROR5
L5 + L7
00001010 FLASHERROR6
L5 + L7 + L8
00001011 UART_STAT_GENERAL_ERROR Remove equipment
that may cause elec-
trical disturbance.
L5 + L6
00001100 UART_BUFFOVERRUN
L5 + L6 + L8
00001101 UART_PARITY
L5 + L6 + L7
00001110 UART_FRAMING
L5 + L6 + L7 + L8 00001111 E_UART_OVERRUN
L4
00010000 E_DRIVERERROR
If the error occurs
repeatedly, contact
Beijer Electronics.
Summary of Contents for C-Key16
Page 1: ...C Key16 Manual MA00645 2002 11 English...
Page 21: ...Drawings Beijer Electronics AB MA00645 21 7 Drawings Outline drawing...
Page 22: ...Drawings 22 Beijer Electronics AB MA00645 C Key16 installation...
Page 23: ...Drawings Beijer Electronics AB MA00645 23 Connection drawing...
Page 24: ...Drawings 24 Beijer Electronics AB MA00645 CAB8...
Page 25: ...Drawings Beijer Electronics AB MA00645 25 CAB21...
Page 26: ...Drawings 26 Beijer Electronics AB MA00645 Text strips...