GB
Switching module RC-SM-4
20
BEIER-Electronic
22.09.2020
Mode 12: Indicator (automatic shutdown), hazard warning
lights, light 1+2
Here the indicators are not controlled via the steering, but via a separate channel
with a 3-position switch. In contrast to mode 11, however, the indicators are
automatically switched off again after an adjustable number of flashes.
How often the indicator should flash is determined by the "digital potentiometer" (see
page 8):
Digital potentiometer value
Shutdown after flashing x times
0
2 x
1
3 x
2
4 x
3
5 x
4
6 x
5
7 x
6
8 x
7
9 x
Left indicator, right indicator and hazard warning lights switch off the other
automatically as soon as they are activated.In addition to the right and left indicators,
2 further outputs for 2 lights, as well as the hazard warning lights (right indicator and
left indicator simultaneously) can be switched.
Assignment of the outputs:
Output 1:
Indicator left
Output 2:
Light 1
Output 3:
Light 2
Output 4:
Indicator right
Control of the functions:
The intermediate areas B and C are not evaluated in this mode.
Short in area A:
Switches indicator left on or off (memory)
Long in area A:
1 x switches light 1 on (memory)
2 x switches light 2 on (memory)
3 x switches light 1 and light 2 off again
Long in area D:
Switches hazard warning lights on or off (memory)
Short in area D:
Switches indicator right on or off (memory)
Indicator left
Light 1 + Light 2
Indicator right
Hazard warning lights
2.0 ms
1.8 ms
1.5 ms
1.2 ms
1.0 ms