Fig. 2.8: <TUBE> menu
Use this menu to set up the Exciter and Tube Simulation. Please refer to Table 2.2 for the structure and the
meanings of the abbreviations. Softkey D (A/B) allows you to compare the current setting with the settings of
the program as it was loaded. The B in the pictogram is displayed in bold whenever you modify a loaded
program. If you are not satisfied with the new setting, you can return to the original program by pressing
softkey D a second time and trying a new setting from there. As soon as you change a value, the B in the
pictogram will once again be displayed in bold. Upon loading a new program, neither A nor B will be high-
lighted as long as no changes have been made.
Display
Function
Parameter
Range
Default Value
EXC
Exciter
Process
0 to 100
0
O/E
Exciter
Odd/Even
1/19 to 19/1
10/10
PRC
Tube
Process
0 to 100
0
TYP
Tube
Type
12AX7, 12AY7, EL34, EL84
12AX7
Tab. 2.2: Fader functions in the <TUBE> menu
2.3 METER mode
Press the Meter key to enter the METER mode.
Fig. 2.9: METER mode
This mode displays the input and output levels of all frequency bands (ascending from left to right) and the
overall levels of the two channels. Information is also shown regarding level changes made by the ULTRA-
DYNE PRO. Gain reductions are displayed as a small bar extending downward from the 0 dB mark. It is
possible to activate the VIRTUOSO mode while in METER mode by pressing softkey A (see 3.4). Softkey D
toggles between the display of the input and output levels. IN or OUT are highlighted accordingly.
2.3.1 Advanced level meter
Press the softkey B (SINGLE) to call up the advanced level meter.
2. OPERATION