13
3. INSTALLATION
The FEEDBACK DESTROYER was carefully packed in the factory and the packaging was designed to
protect the unit from rough handling. Nevertheless, we recommend that you carefully examine the packaging
and its contents for any signs of physical damage, which may have occurred in transit.
+
If the unit is damaged, please do not return it to us, but notify your dealer and the shipping
company immediately, otherwise claims for damage or replacement may not be granted. Ship-
ping claims must be made by the consignee.
3.1 Rack mounting
The Behringer FEEDBACK DESTROYER fits into one standard 19" rack unit of space (1 3/4"). Please allow
at least an additional 4" depth for the connectors on the back panel.
+
Be sure that there is enough air space around the unit for cooling and please do not place the
FEEDBACK DESTROYER on high temperature devices such as power amplifiers etc. to avoid
overheating.
3.2 Mains voltage
Before you connect your FEEDBACK DESTROYER to the mains, please make sure that your local
voltage matches the voltage required by the unit! The fuse holder on the female mains connector has 3
triangular markers, with two of these triangles opposing each other. Your FEEDBACK DESTROYER is set to
the operating voltage printed next to these markers, and can be set to another voltage by turning the fuse
holder by 180°. CAUTION: this instruction does not apply to export models exclusively designed, e.g.
for 115 V operation!
3.3 Audio connections
All audio inputs/outputs on the Behringer FEEDBACK DESTROYER are unbalanced. Always use shielded
cables of relatively short lengths to avoid interference problems.
+
Please ensure that only qualified persons install and operate the FEEDBACK DESTROYER. During
installation and operation the user must have sufficient electrical contact to earth. Electrostatic charges
might affect the operation of the FEEDBACK DESTROYER!
All connectors are of the 6.3-mm mono phone jack type. If you use stereo plugs, please connect sleeve and
ring.
Tip = Signal
Sleeve = GND / Shielding
Tip
Sleeve
Strain Relief Clamp
Unbalanced Operation with 1/4" Connector
Fig. 3.1 Mono phone plug
3. INSTALLATION