background image

9

EUROPOWER PMX1000/PMX3000/PMX5000

4. INSTALLATION

Fig. 4.2: 1/4" TRS connector

Fig. 4.3: XLR connectors

Fig. 4.4: 1/4" mono plug for footswitch

4.3 Loudspeaker connections

Your power mixer is equipped with high-quality Neutrik NL4MP

SPEAKON

®

  connectors,  which  ensure  safe  and  trouble-free

operation. The SPEAKON

®

 connector was especially developed

for  high-power  loudspeakers.  Once  it  is  plugged  in,  it  safely

locks  into  position  and  cannot  be  accidentally  disengaged.  It

prevents  the  occurrence  of  electrical  shock  and  ensures  the

correct polarity. Each of the SPEAKON

®

 jacks carries only the

assigned  single  signal  (see  the  information  given  on  the  rear

panel of the power mixer).

Fig. 4.5: SPEAKON

®

 connector

Please be sure to only use commercial SPEAKON

®

 cables (type

NL4FC) for connecting your loudspeakers to the power mixer.

Please  check  the  pin  assignment  of  your  loudspeakers  and

cables dependent on the PMX speaker output you choose.

287387$

1+

1-

2+

2-

0$,1/

x

x

021,725

x

x

0212

x

x

287387%

x

x

287387%

1+

1-

2+

2-

0$,15

x

x

0212

x

x

0212

x

x

%5,'*(

x

x

(85232:(530;30;30;

Tab.  4.1:  Polarity  configuration  of  speaker  connectors

OUTPUT B

OUTPUT A

+1

+1

-1

-1

BRIDGE

16 

 8 

+1

+2

Fig. 4.6: SPEAKON

®

 pin assignment

All manuals and user guides at all-guides.com

Summary of Contents for Europower PMX1000

Page 1: ...Version 1 0 December 2003 User s Manual ENGLISH EUROPOWER PMX1000 PMX3000 PMX5000 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...hat produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Pr...

Page 3: ...ce All of this will enable you to fully unfold your creativity without being hampered by budget constraints We are often asked how we can make it to produce such high grade devices at such unbelievably low prices The answer is quite simple it s you our customers Many satisfied customers means large sales volumes enabling us to get better conditions of purchase for components etc Isn t it only fair...

Page 4: ...details The mains connection is made using the enclosed power cord and a standard IEC receptacle It meets all of the international safety certification requirements 2 CONTROL ELEMENTS Please make sure that all units have a proper ground connection For your own safety never remove or disable the ground conductor from the unit or on the AC power cord 1 1 3 Warranty The EUROPOWER s serial number is l...

Page 5: ...s place only if a plug is inserted into the corresponding jack 1 4 stereo plug tip signal output ring input All mono input channels are equipped with inserts The stereo channels have a TRIM control for gain adjustment with the input sensitivity ranging from 20 to 20 dB PMX1000 The stereo channels 5 6 and 7 8 feature an additional XLR connector for microphones whose gain can be set from 0 to 40 dB ...

Page 6: ... a sufficiently high level Make sure that the Clip LED illuminates with signal peaks only If it is constantly illu minated the effects processor is overloading which can lead to unpleasant distortion The FX SEND fader PMX1000 or FX FX 1 2 fader PMX3000 PMX5000 controls the level sent to the effects module and to the FX SEND output jacks The effects display always reads the currently selected prese...

Page 7: ...acks and with the effects processor so that both can be controlled together by one control For the FX signals use a 1 4 stereo plug connected as follows FX1 tip FX2 ring The PHONS CTRL connector allows you to connect a pair of stereo headphones or an active monitor speaker 2 5 Rear panel The mains connection is via a standard IEC receptacle An appropriate power cord is supplied with the unit FUSE ...

Page 8: ...y differ in the length of reverb time FLANGER REVERB The combination of flanger and reverb effects PHASER REVERB The combination of a classic stereo phaser and a reverb effect Here too the phaser is combined with different reverb types ROTARY SPEAKER REVERB The combination of a rotary speaker effect and reverb program DELAY REVERB Delay and reverb is the most common combination for vocals solo gui...

Page 9: ...the correct polarity Each of the SPEAKON jacks carries only the assigned single signal see the information given on the rear panel of the power mixer Fig 4 5 SPEAKON connector Please be sure to only use commercial SPEAKON cables type NL4FC for connecting your loudspeakers to the power mixer Please check the pin assignment of your loudspeakers and cables dependent on the PMX speaker output you choo...

Page 10: ...tage monitors Use the footswitch to enable disable the effects processor Fig 5 2 Bridged mono operation This illustration shows the power mixer with a sub woofer connected to OUTPUT B For a bridged mono operation to OUTPUT B the AMP MODE selector switch must be set to its lower position BRIDGE A separate stereo power amp BEHRINGER EUROPOWER EP1500 connected to the preamp main outputs delivers the ...

Page 11: ...nd the monitor signals separately from each another Each of these signals is then sent to two speakers wired in parallel Fig 5 4 Standard set up example The illustration shows just one channel configuration possible comprising mono and stereo sources and additionally the tape input output for recording the mix signal or feeding in a playback signal 5 WIRING EXAMPLES All manuals and user guides at ...

Page 12: ...5 Expanded set up This application is an expanded set up based on the standard set up as shown in fig 5 4 and provides additional connection options Again this is just an example which can be expanded in various ways All manuals and user guides at all guides com ...

Page 13: ...3 Mains voltage Power consumption 500 W Fuse 3 15 A 220 240 V 5 A 100 110 V Mains connector 102 dB 106 dB A weighted 88 dB 91 dB A weighted 84 dB 86 dB A weighted RCA approx 1 kΩ 134 dB 136 dB A weighted 131 5 dB 134 dB A weighted 129 dB 131 dB A weighted 10 Hz 200 kHz 3 dB 10 Hz 155 kHz 1 dB Standard IEC receptacle 700 W 4 A 220 240 V 6 3 A 100 110 V 85 250 V 50 60 Hz 1 4 TRS connectors unbalance...

Page 14: ...imilar parts 4 Damages defects caused by the following conditions are not covered by this warranty s improper handling neglect or failure to operate the unit in compliance with the instructions given in BEHRINGER user or service manuals s connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the product is used ...