Adjusting the digital controller
15
6
Adjusting the digital controller
When the digital controller is switched on with the I/O button, the actual value is
displayed.
Pressing the X button displays the setpoint for 5 seconds. During this time, the
setpoint can be adjusted with the + and - buttons; once the final adjustment has
been made, the actual value is automatically displayed again.
The flow temperature is displayed by pressing the X button twice. After 4
seconds, the display returns automatically to the actual value.
If no voltage is applied across terminals 11 and 12, the display shows
-0.-.
If the
swimming pool sensor circuit is broken, the display shows --.-- . In the event of
a sensor short circuit, the display shows a value of
0. ....
If the flow sensor circuit
is broken, the display shows 99.9. In the event of a sensor short circuit, a value
of below 2°C is displayed.
In order to avoid disruption, switching and adjusting functions have a slight time
delay.