19
DETAILED SPECIFICATIONS
Ambient temperature:
23°C ±5°C (73.4°F ±9°F); Relative temperature:
≤
75%
Accuracy:
±(% of r digits)
Maximum voltage between input terminal and earth ground:
1000V ac True-rms or 1000V dc.
�
Fuse for mA µA input:
F1 0.5A H 1000V fast-fuse, (
Φ
6.3×32)mm
�
Fuse for A input:
F2 11A H 1000V fast-fuse, (
Φ
10×38)mm
Maximum display:
Digital 5999 counts, updates 3/seconds.
Analog pointer display:
61 segments. Updates 20 times/seconds.
Over-range indication:
OL
Range:
Automatic and Manual
Altitude:
Operating
≤
2000m
Operating temperature:
0°C~+40°C (32°F~104°F)
Relative humidity:
0°C~+30°C (32°F~86°F)
≤
75%; +30°C~+40°C (86°F~104°F)
≤
50%
Storage temperature:
-10°C~+50°C (14°F~122°F)
Electromagnetic compatibility:
In an RF filed of 1V/m = Specified accuracy ± 5%
Battery:
9V, 6F22, NEDA1604 or equivalent
Low battery indication:
Dimensions (L x W x H):
182 mm x 90 mm x 45 mm (7.2 in x 3.5 in x 1.8 in)
Weight:
Approximately 354g (0.78 lb) with batteries installed
1. DC Voltage Measurement
Range
Resolution
Best Accuracy
600.0mV
0.1mV
±(0.5%+3 LSD)
6.000V
1mV
±(0.5%+2 LSD)
60.00V
10mV
600.0V
100mV
1000V
1V
±(1.0%+2 LSD)
Input impedance:
Around 10M
Ω
;
Overload protection:
±1000V