BEGLEC JBSYSTEMS Light TWINBEAM COLOR Operation Manual Download Page 3

ENGLISH

USER MANUAL

JB SYSTEMS

®

1/47

TWINBEAM COLOR Laser

Thank you for buying this JB Systems

®

product. To take full advantage of all possibilities and for your own

safety, please read these operating instructions very carefully before you start using this unit.

FEATURES

This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.

This device has been designed to produce decorative effect lighting and is used in light show systems.

Produces 2 synchronized laser beams

Generates dynamic 3 color laser shows, perfect for fixed and mobile installations.

RGY (Red, Green, Yellow) Class 3B Laser

o

650nm Red 80mW beam

o

532nm Green 100mW beam

o

Mixed Yellow 80mW beam

Several working modes:

o

DMX controlled, 8channels

o

Stand-alone with built-in microphone

o

Stand-alone automatic mode

Preprogrammed multi-color laser shows

DMX-addressing with LED display

Complies to EN/IEC 60825-1 for Laser Safety

BEFORE USE

Before you start using this unit, please check if there’s no transportation damage. Should there be any, do
not use the device and consult your dealer first.

Important:

This device left our factory in perfect condition and well packaged. It is absolutely necessary

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects
or problems caused by disregarding this user manual.

Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user
manual.

Check the contents:

Check that the carton contains the following items:

TWINBEAM COLOR Laser unit

2 keys (for key switch)

Mains cable

Operating instructions

SAFETY INSTRUCTIONS:

CAUTION:

To reduce the risk of electric shock, do not remove the top cover.

No user-serviceable parts inside. Refer servicing to qualified service
personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use
or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instructions in the literature accompanying this
appliance.

This symbol means: indoor use only.

This symbol means: Read instructions.

CAUT ION

ENGLISH

USER MANUAL

JB SYSTEMS

®

2/47

TWINBEAM COLOR Laser

This symbol determines: the minimum distance from lighted objects. The minimum distance between
light-output and the illuminated surface must be more than 1 meters.

To protect the environment, please try to recycle the packing material as much as possible.

A new light effect sometimes causes some unwanted smoke and/or smell. This is normal and disappears
after some minutes.

To prevent fire or shock hazard, do not expose this appliance to rain or moisture.

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance or may even cause damages.

This unit is for indoor use only.

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign
object enters the unit, immediately disconnect the mains power.

Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture
must be fixed at least 50cm from surrounding walls.

Don’t cover any ventilation openings as this may result in overheating.

Prevent use in dusty environments and clean the unit regularly.

Keep the unit away from children.

Inexperienced persons should not operate this device.

Maximum save ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.

The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare hands during its
operation.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Allow the device about 10 minutes to cool down before replacing the bulb or start servicing.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

The electrical installation should be carried out by qualified personal only, according to the regulations for
electrical and mechanical safety in your country.

Check that the available voltage is not higher than the one stated on the rear panel of the unit.

The power cord should always be in perfect condition. Switch the unit immediately off when the power cord
is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.

Never let the power-cord come into contact with other cables!

This fixture must be earthed to in order comply with safety regulations.

Don’t connect the unit to any dimmer pack.

Always use an appropriate and certified safety cable when installing the unit.

In order to prevent electric shock, do not open the cover. Apart from the lamp and mains fuse there are no
user serviceable parts inside.

Never

repair a fuse or bypass the fuse holder.

Always

replace a damaged fuse with a fuse of the same

type and electrical specifications!

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

The housing and the lenses must be replaced if they are visibly damaged.

Please use the original packing when the device is to be transported.

Due to safety reasons it is prohibited to make unauthorized modifications to the unit.

Important:

Never look directly into the light source! Don’t use the effect in the presence of persons suffering

from epilepsy.

Summary of Contents for JBSYSTEMS Light TWINBEAM COLOR

Page 1: ...LEC cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de instrucciones Manual do utilizador EN FR NL DU ES PT ...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GERÄTS Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes ES DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais PT COMO DESFAZER S...

Page 3: ...the packing material as much as possible A new light effect sometimes causes some unwanted smoke and or smell This is normal and disappears after some minutes To prevent fire or shock hazard do not expose this appliance to rain or moisture To avoid condensation to be formed inside allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport Condense som...

Page 4: ...used to connect the Twinbeam laser with the next unit in the DMX chain 7 DISPLAY shows the selected DMX address when the unit is in DMX mode Shows 3 horizontal lines when the unit is in stand alone mode 8 DIP SWITCHES switches 1 8 are used to set the DMX address between 000 and 255 Switch 9 is not used and switch 10 is used to select stand alone or DMX mode 9 AUTO MUSIC SWITCH when the unit is use...

Page 5: ...able ex JB Systems ref 7 0063 To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables this simply won t work Each effect in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode This is how you must setup and use the Twinbeam laser Co...

Page 6: ... prior notice You can download the latest version of this user manual on our website www beglec com FRANÇAIS MODE D EMPLOI JB SYSTEMS 8 47 TWINBEAM Laser Merci d avoir choisi ce produit JB Systems Pour votre sécurité et pour une utilisation optimale de toutes les possibilités de l appareil lisez attentivement cette notice avant utilisation EN VOUS INSCRIVANT POUR LA LETTRE D INFORMATION VOUS SEREZ...

Page 7: ...que par du personnel qualifié et conformément aux règlements de sécurité électrique et mécanique en vigueur dans votre pays Assurez vous que la tension d alimentation de la source d alimentation de la zone dans laquelle vous vous trouvez ne dépasse pas celle indiquée à l arrière de l appareil Le cordon d alimentation doit toujours être en parfait état Mettez immédiatement l unité hors tension si l...

Page 8: ...nction du son de la musique détecté par le microphone interne 15 CROCHETS DE SUPPORT avec 2 poignées sur les deux côtés pour accrocher l appareil et un trou de fixation pour fixer un crochet de montage 16 SORTIE LASER À cet endroit le laser sort de l appareil assurez vous de NE JAMAIS REGARDER à l intérieur de l appareil par cette ouverture pendant que l effet laser est allumé 17 ÉTIQUETTE ATTENTI...

Page 9: ...ment configurer le Laser Twinbeam Connectez l appareil sur un contrôleur DMX en utilisant un câble DMX approprié Déterminez quelle adresse DMX le laser a besoin Mettez l interrupteur DIP numéro 10 sur DMX Vous devrez programmer l adresse DMX de départ avec les interrupteurs DIP de 1 à 8 Chacun de ces interrupteurs possède une valeur DMX correspondante inscrite en dessous Vous pouvez combiner les v...

Page 10: ...réalable Vous pouvez télécharger la dernière version de ce mode d emploi sur notre site Web www beglec com NEDERLANDS HANDLEIDING JB SYSTEMS 16 47 TWINBEAM Laser Hartelijk dank voor de aankoop van dit JB Systems product Om ten volle te kunnen profiteren van alle mogelijkheden en voor uw eigen veiligheid gelieve de aanwijzingen zeer zorgvuldig te lezen voor U begint het apparaat te gebruiken DOOR U...

Page 11: ...tend uitgevoerd te worden door bevoegd personeel volgens de in uw land geldende regels betreffende elektrische en mechanische veiligheid Controleer dat de beschikbare spanning niet hoger is dan die aangegeven op de achterzijde van het toestel De elektrische kabel behoort altijd in uitstekende staat te zijn Zet het apparaat onmiddellijk af als de elektrische kabel gekneusd of beschadigd is De kabel...

Page 12: ...rdt door de interne microfoon 15 OPHANGBEUGEL met 2 knoppen langs weerskanten om het toestel vast te maken en een gat om een bevestigingshaak aan vast te maken 16 LASERUITGANG Hier verlaat de laserstraal de behuizing kijk NOOIT binnenin het toestel doorheen deze opening als het lasereffect aan staat 17 WAARSCHUWINGSLABEL Waarschuwing Klasse 3B laser Laserstraling bij opening Vermijd blootstelling ...

Page 13: ...ller gedecodeerd moeten worden Zo moet je de Twinbeam laser opstellen en gebruiken Sluit het toestel aan op een DMX controller met een geschikte DMX kabel Bepaal welk DMX adres de laser nodig heeft Zet DIP schakelaar nummer 10 in DMX positie Je moet het DMX startadres ingeven met de DIP schakelaars 1 tot 8 Iedere schakelaar hiervan heeft een overeenkomstige DMX waarde onder zich Je kan de waarden ...

Page 14: ... 3B Laser SafetyStandaard EN60825 1 1994 A1 2002 A2 2002 Afmetingen 26 x 30 x 10cm Gewicht 5 8 kg Elke inlichting kan veranderen zonder waarschuwing vooraf U kan de laatste versie van deze handleiding downloaden via onze website www beglec com DEUTSCH BEDIENUNGSANLEITUNG JB SYSTEMS 24 47 TWINBEAM Laser Vielen Dank dass Sie sich für den Erwerb dieses JBSystems Produkt entschieden haben Bitte lesen ...

Page 15: ...cht mit anderen Kabeln in Berührung kommen lassen Zur Einhaltung der Sicherheitsbestimmungen muß das Gerät geerdet sein Gerät nicht an einen Dimmer anschließen Ausschließlich vorschriftsmäßige Kabel zur Installation verwenden Gerät nicht öffnen Abgesehen vom tausch des Leuchtmittels und der Sicherung sind keine zu wartenden Bauteile im Gerät enthalten Sicherung niemals reparieren oder überbrücken ...

Page 16: ...en Abständen überprüft werden Sicherstellen dass sich keine unbefugten Personen unterhalb des Geräts befinden während es installiert oder gewartet wird Gerät in gut belüfteter Position installieren weit entfernt von entflammbaren Materialien und oder Flüssigkeiten Einen Seitenabstand von mindestens 50cm einhalten Gerät außerhalb der Reichweite von Personen und nicht in niedrigen Durchgängen oder i...

Page 17: ...25 189 195 Muster 26 DEUTSCH BEDIENUNGSANLEITUNG JB SYSTEMS 30 47 TWINBEAM Laser 196 202 Muster 27 203 210 Muster 28 211 216 Muster 29 217 223 Muster 30 224 230 Muster 31 231 251 Muster 32 252 255 Muster 33 3 000 255 Rotieren des Musters 4 000 255 Zoom Mustergröße klein bis gross 5 000 255 Pan Bewegung X Axe Links nach rechts Wert 128 mittlere Position 6 000 255 Tilt Bewegung Y Axe Oben nach unten...

Page 18: ...usa en sistemas de iluminación de espectáculos 2 rayos láser sincronizados Produce espectáculos impresionantes con 3 comores perfecto para instalaciones fijas y móviles Láser clase 3B RGY Rojo Verde Amarillo o rayo rojo de 650nm y 80mW o rayo verde de 532nm y 100mW o rayo mezclado amarillo de 80mW Diversos modos de funcionamiento o Controlado por DMX 8 canales o Independiente con micrófono integra...

Page 19: ...perfectas condiciones apague el aparato inmediatamente cuando el cable de alimentación esté roto o dañado Debe ser substituido por el fabricante su servicio técnico o otra persona cualificada Nunca deje el cable de alimentación entrar en contacto con otros cables Esta instalación debe ser conectada a tierra para cumplir con las regulaciones de seguridad No conecte la unidad a ningún paquete de red...

Page 20: ...de instalación deben ser usados el aparato instalado debería ser inspeccionado regularmente por seguridad Asegúrese de que el área por debajo del sitio de instalación está libre de personas ajenas durante el montaje desmontaje y reparación Coloque la instalación en un sitio bien ventilado lejos de cualquier material inflamable y o líquidos La instalación debe ser fijada al menos a 50cm de los muro...