SOLUTIONS IN CASE OF PROBLEMS
LED
green
LED
red
Ref : HYB01-5
Ref :
HYB01-10
If there is a problem with your product, please refer to the diagrams below and the solutions table.
17
Functions
Green led
Red led
Encountered problem
Solution
Initial state
Blinks once
Blinks once
Connection problem
Unplug and re-plug your
charging cable.
Connected
Flashes
quickly
LED off
Connection problem
The voltage detected at the
input of the transmission box
is 12 V
Unplug and re-plug your
charging cable.
Normal recharge
Flashes slowly
and steadily
LED off
Connection problem
The voltage detected at the
input of the transmission box
is 6 V
Unplug and re-plug your
charging cable.
End of recharge
LED fi
xed
LED off
Connection problem
The voltage detected at the
input of the transmission box
is 9 V
Unplug and re-plug your
charging cable.
Abnormal
communication
LED off
Flashes once
every 2 seconds
The voltage detected at the
input of the transmission box
is abnormal, the charger then
enters a protection state.
Unplug and re-plug your
charging cable.
When the voltage detected at
the input of the transmission
box returns to normal, the
charger will automatically
operate again.
Under pressure
LED off
Flashes twice
every 2 seconds
When the voltage detected at
the input of the transmission
box is less than 75 V ± 10 V
for 0.1 second, the output
current is cut off.
Unplug and re-plug your
charging cable.
When the voltage rises to 90V
± 10V, the recharging system
restarts after a delay of 5
seconds.
Over voltage
LED off
Flashes three
times every 2
seconds
When the voltage detected at
the input of the transmission
box is greater than 270 V ± 10
V for 0.1 second, the output
current is cut off.
Unplug and re-plug your
charging cable.
When the voltage drops below
254 V ± 10 V, charging will
resume after a 5 second
delay.
Leak
LED off
Flashes four
times every 2
seconds
When the current detected at
the input of the transmission
box is greater than 25 ± 5
mA, the output current is cut
off.
Unplug and re-plug your
charging cable.
Once the fault is resolved, the
charger will need to be
powered on again to continue
charging.
Over current
LED off
Flashes fi
ve
times every 2
seconds
The current detected at the
input of the transmission box
is between the overcurrent
value of 12 Ah and 14 Ah.
After
the fi
rst detection, the
charger turns off for 5
seconds.
After a new test, if the
transmission box encounters
the same problem, it will
deactivate for 10 seconds.
After 3 times of repetitions,
the red light comes on and the
load is cut off.
Unplug and re-plug your
charging cable.
Power plug /
PCB overheating
LED off
Flashes six times
every 2 seconds
When the temperature of the
power plug or the printed
circuit is above 85 for a
period of 2 seconds, the
charger switches off.
Unplug and re-plug your
charging cable.
It must wait for the
temperature to drop below 65
for a period of 2 seconds to
return to normal operation.
The earth socket
is not connected
/
Led on
Charging takes place but the
warning light will stay on.
Please contact a professional
to check your electrical
installation.
Power-on self-
test failed
LED off
Flashes eight
times every 2
seconds
The charging cable is unable
to charge.
Unplug and re-plug your
charging cable.
Summary of Contents for HYB01-10
Page 14: ...14 TECHNICAL CHARACTERISTICS...
Page 15: ...15 TECHNICAL CHARACTERISTICS...
Page 22: ...22 CARACTER STICAS T CNICAS...
Page 23: ...26 CARACTER STICAS T CNICAS...
Page 30: ...30 TECHNISCHE EIGENSCHAFTEN...
Page 31: ...31 TECHNISCHE EIGENSCHAFTEN...
Page 38: ...38 CARATTERISTICHE TECNICHE...
Page 39: ...39 CARATTERISTICHE TECNICHE...
Page 46: ...46 TECHNISCHE EIGENSCHAPPEN...
Page 47: ...47 TECHNISCHE EIGENSCHAPPEN...
Page 54: ...54 CARACTER STICAS T CNICAS...
Page 55: ...55 CARACTER STICAS T CNICAS...
Page 59: ...Plus d infos plus de produits More info more products www beeper fr...