14
GAS REQUIREMENTS
GAS REQUIREMENTS
ASSEMBLING THE BARBECUE
WARNING!
• If an LPG bottle is to be stored in the enclosure
under the barbecue unit, it must be isolated from the
barbecue unit with a non-combustible panel�
• Ventilation requirements for cylinder storage are:
Where of sheet metal or similar impervious construction
there shall be ventilation openings at the top and bottom
of the enclosure or recess, each opening providing a free
area of at least 200cm
2
for every cylinder enclosed�
• For LP / Propane installations having enclosed cabinetry
below the separation panel that does not contain a gas
bottle, low level venting must be installed� This is to
allow the gas which is heavier than air to escape from
the enclosure in the situation where there may
be a leak� A minimum opening of 200cm
2
is required�
Setting up the barbecue
Setting up the barbecue in mounting enclosure
• A match holder with attached chain has been included
with the instruction manual� This is provided for manual
ignition in the event the automatic ignition does
not work� The free end of chain is required to be
permanently fixed to the installation in a location that
enables the match holder to reach each burner (refer to
page 16 for manual lighting instructions)�
1� Remove all components from box�
2� Attach heat shield to rear of unit by inserting the
three top tabs into the rear holes and sliding the
shield down�
3� Install flame tamers (under grills) and fix back edge of flame
tamer into the heat shield panel�
4� Fit oil reservoirs at front of barbecue�