Beech Ovens
Page 56
28/07/2011 (C)
RND-REC-RGO Manual (R1)
Confidential and Proprietary
19mm reticulated Gas
supply connected here.
Char Grill manifold
NOTE:
When coiling the lead to the Thermocouple, be sure not to kink or damage the
lead. The lead is to be routed in a tidy manner using the supplied clips and
cable ties under the oven base ensuring that it is not attached to other cables,
metallic or sharp objects.
Connect to reticulated gas supply at the 19mm flare fitting at the base of the gas
cabinet. An isolation valve should be fitted prior to the gas control cabinet to allow gas
supply to be completely isolated from the appliance. Purging of the gas supply lines
may also be necessary. Check with your Gas installer that these items are done in
accordance with local regulation. NOTE: Gas can be odourless in new installations.
NOTE:
Connection of the Gas supply line should be carried out by qualified
personnel. Be sure to check for correct gas type and set-up for local gas
supply. Be sure that the lines are purged in accordance with local regulation.
Char Grill Connection
A separate gas supply is required for the Char
Grill. This can be taken from the main gas supply
line, though care must be taken to ensure the
correct line size is achieved to handle the gas
load.
(Refer to
General Technical Details
at the
rear of this manual)
This connection should have an isolation valve
fitted prior to the gas manifold. For Australian
installations a
„slam-shut‟ valve is supplied to
meet requirements of AS5601.