Beech Ovens
Page 40
28/07/2011 (C)
RND-REC-RGO Manual (R1)
Confidential and Proprietary
Keeping in mind to leave enough room for the 125mm flexible tube, cut a hole in the
front façade panel big enough to house the vent box.
NOTE:
The vent
MUST
be below the oven mouth and in the same room as
the oven mouth. It cannot be installed in an adjacent room.
The reason for having the vent under the mouth of the oven is to ensure that the
pressure into the oven mouth is the same as that supplied to the tube burner, thus
eliminating the pressure differential through the tube burner hole.
Access is still required to the underside of the oven, though with the ventilation panel
installed; this can now be from behind the oven or in an alternate location other than in
the front face of the oven.
The control cabinet can also be remotely located as long as it is accessible for both the
operator and maintenance staff.
Hole for vent box
(130mm x 130mm for sheet wall)
(145mm x 145mm for stud wall)
Vent panel
MUST
be within
this area