Manual control
Figure 6.1 Flow chart of debugging for the first time
Confirm the motor-pump wiring:
1. Press the “I” to check the outlet water yield;
2. Press the “O” key to change the connection order;
3. Press the “I” again to check the outlet water yield;
4. Press the “O” and then choose the large water yield connection as the motor-pump wiring.
Modify the motor-pump parameters and start voltage:
Modify these parameters (F0.05, F0.06, F0.07, F0.08, F0.09, F0.10) according to the
parameters of solar cell array and the pump nameplate parameters. (According to the
situation to adjust the F0.02, F0.04)
Select run
command source
Set
F0.00 = 2
Set
F0.00=0
Water-level automatic control
Press“I” key
to start
Press “O”
key to stop
Water-level
automatic control
through Keypad
Start/Stop
Press “I” key
to start
According to chapter “4.5” description
to connect the water-level detection
line and set F0.12
According to water-level to operate or
sleep down automatically
Press “O”
key to stop
According to
chapter “4.5”
description to
connect the
water-level
detection line
and set F0.12
Set F0.00=1
*If you do not use
S1, S2, S3, S4, You
need to short
the S1S2 and COM.