Instruction manual
|
EMS-56/EMS-57
|
Beckmann GmbH
DIP-switch No.
Valence
1
1
2
2
3
4
4
8
5
16
Table 1:
Basic Time DIP-switch settings
Example:
For a time release of 22 minutes, you have 1 minute (minimum time), plus:
DIP switch
Value
Position
Plus minutes
1
1
ON
1
2
2
OFF
0
3
4
ON
4
4
8
OFF
0
5
16
ON
16
Sum:
21
Table 2:
Example for the time -setting
Time-factor
In order to program time-periods of more than 32 minutes, you have to set the
DIP-switch 6 to “ON” to activate the time-factor. This will multiply the time by factor 10.
In the example above, you will get a time of 220 minutes per coin.
Minimum insertion
For the minimum insertion, the DIP-switches 7 and 8 are responsible. The minimum
insertion indicates the minimum number of coins, that have to be inserted at least.
The minimum insertion has to be programmed referring to Figure 4: Minimum insertion.
Figure 4:
Minimum insertion
Technical data
Power supply
230V AC
Mains frequency
50/60 Hz
Power consumption
3W
Max. switched power
Max. 16A/230V
Operating temperature
0 up to 40 °C
Operating humidity
30 up to 70 %
Weight
3,5 kg
Dimensions
162 x 260 x 110 mm
Table 3 :
Technical data
Page 8