background image

Product Description of BRT-410

Page 1 of 5

Shenzhen Asia Bright Industry co., Ltd., Building 10, Asia Industrial Park, Gangtou, Bantian, Shenzhen, China.

www.a-brt.com

[email protected].

© 2015 All rights reserved. Subject to change without notices.

Timer Switch with Daily Multiple Period Settings
(No Neutral Required)

Model #

BRT-410

Features:

BRT-410 is the most advanced timer switch. It is controlled by a micro controller unit and has very

accurate timing capability. It is designed for easy installation and retrofit, directly fit into standard

wall box where both hot wire and neutral wire are present.

Two buttons for easy operation and controls two loads;

Hidden panel of 9 keypads for setting up timer to prevent inadvertent changes;

Up to 16 preset timing periods with precise On and Off time each day;

LCD display showing the current clock time, timing period #, and the current status of the

switch;

Good for all kinds of loads (Resistive, inductive, and capacitive);

ABS-V0 flame resistance material; and

Classical 86 series design and high quality build.

Front View, Back View, and Hidden Panel

Fig. 1 and Fig. 2 show the front view and the back view of the wall mount unit of BRT-410 timer

switch respectively.

Fig. 1

Front View

Fig. 2

Back View

Summary of Contents for BRT-410

Page 1: ...ly fit into standard wall box where both hot wire and neutral wire are present Two buttons for easy operation and controls two loads Hidden panel of 9 keypads for setting up timer to prevent inadvertent changes Up to 16 preset timing periods with precise On and Off time each day LCD display showing the current clock time timing period and the current status of the switch Good for all kinds of load...

Page 2: ... On Off button is pressed again If there is no timing period being set the load will be turned off immediately and the display will show Off and the load and If there is timing period being set the load will be turned on automatically during the preset timing period Press the On Off button will cancel the timing operation and turn off the load immediately Fig 3 Hidden 9 Keypad Panel As shown in Fi...

Page 3: ... Guide BRT 410 timer switch requires both hot wire and neutral wire for installation Hot wire ACL Coming from the power line with 220V Neutral wire ACN Usually coming with the hot wire and Load wires Going to the load Fig 4 Wiring Diagram of Wall Mount Unit Warning Please make sure power is turned off before starting installation Fig 4 shows the wiring diagram and Fig 5 shows the step by step inst...

Page 4: ...e I button until the display shows ON and 01 and the displayed hours flash Press or to adjust the required on hours Press SET button the displayed minutes flash and use or to adjust the required on minutes and 3 2 Set up the Off time Right after setting up the on time press SET button again and the display shows OFF and 01 and the displayed hours flash Press or to adjust the required off hours Pre...

Page 5: ...ing convenience and safety to our daily life and work They have wide applications at various locations such as homes schools laboratories hospitals offices etc The typical application scenes include Schools Automatically ring the bells according to a fixed timetable to relieve manual intervention Hospitals or Laboratories Automatically turn on and turn off UV disinfection equipment to isolate oper...

Reviews: