Product Description & Operating Manual EMS 13x / 23x / 33x
Page 20
Beckmann GmbH © 2003
3.2.3 Sub-menu 3 Prices
1.
Minimum amount normal
[C]
Þ
Minimum amount for the normal rate [0,01..655,35 €]. This
value can be increased and decreased in 1 Cent intervals. Standard: 5 €.
2.
Time normal
[C]
Þ
Amount of vended time for minimum amount normal
[1Sec..1092min15sec]. This value can be increased and decreased in 1 second intervals.
Standard: 5 minutes.
3.
Minimum amount Happy-Hour
[C]
Þ
Minimum amount for the Happy-Hour rate
[0,01..655,35 €]. This value can be increased and decreased in 1 Cent intervals. Standard: 5 €.
4.
Happy-Hour cash time [C]
Þ
Amount of vended time for the Happy-Hour minimum amount
when paying cash [1Sek..1092min15sek]. This value can be increased and decreased in 1
second intervals. Standard: 6 minutes.
5.
Happy-Hour card time
[C]
Þ
Amount of vended time for the Happy-Hour minimum amount
when paying with Happy-Hour card [1Sek..1092min15sek]. This value can be increased and
decreased in 1 second intervals. Standard: 5 minutes.
6.
Discount mode [D]
Þ
When set to YES, the discount system is activated. The Happy-Hour
mode is turned off. Additional information can be found in “ The EMS three-stage rate
system” p.24 Standard = NO
7.
Level 2 at xx
[C]
Þ
This parameter defines the amount at which a rebate at level 2 is valid
[0,01..655,35 €]. Standard: 10 €.
8.
Time level 2
[C]
Þ
Vended time for level 2 rebate [1Sek..1092min15sek]. Standard 12 min.
9.
Level 3 at xx [C]
Þ
This parameter defines the amount at which a rebate at level 3 is valid
[0,01..655,35 €]. Standard: 20 €.
10.
Time level 3
[C]
Þ
Vended time for level 2 rebate [1Sek..1092min15sek]. Standard 25 min.
11.
Token value[C]
Þ
Defines token value [0..99 €]. Standard: 5 €.
12.
Charge off interval [C]
Vending interval for customer and personnel cards. Standard: 1 €.
13.
Happy-Hour card [D]
If set to YES, customers paying with card receive Happy-Hour rates.
Standard NO. This parameter cannot be used if the Dicount mode is activated (M3N5).
14.
Maximum card charge [C]
Þ
Customers and staff can continue to recharge their cards with
coins as long as this value has not been reached. For example, if a maximum value of 100€
has been set and the customer has a credit of 99€, inserting 5€ will result in a credit of 104€, at
which point continued charging is no longer allowed. If this value is set to zero, the customer
charging function is disabled.